1.2.2.7 The requirements of § 25.1309 are applicable to powerplant installations. The specific applicability and exceptions are stated in § 25.901(c). Section 25.901(c) states that § 25.1309(b) does not apply to propeller debris release failures; those failures are addressed by § 25.905(d) and 14 CFR part 35. Section 25.1309(b) does not apply to uncontained engine rotor failure, engine case rupture, or engine case burn-through failures addressed by §§ 25.903(d)(1) and 25.1193 and 14 CFR part 33.
1.2.2.8 In accordance with § 25.901(d), the requirements of § 25.901(c) and hence § 25.1309 are applicable to auxiliary power unit installations.
1.2.2.9 The fuel system is part of the powerplant installation and therefore must comply with § 25.1309. In addition, fuel systems must comply with § 25.954, Fuel system lightning protection, and § 25.981, Fuel tank explosion prevention. Section 25.954 provides a standard for lightning protection of both fuel tank structure and fuel tank systems. Refer to AC 25.954-1, Transport Airplane Fuel System Lightning Protection, for guidance on the safety assessment of fuel tank lightning protection. Section 25.981 provides standards for the prevention of ignition sources, other than lightning, within the fuel tanks of transport category airplanes. Refer to AC 25.981-1D, Fuel Tank Ignition Source Prevention Guidelines, for guidance on the safety assessment of fuel system ignition sources, other than lightning.
1.2.2.10 Section 25.1309, including the no-single-failure requirement, applies to structural elements in systems, even though those structural elements may also be required to meet the fatigue and damage tolerance criteria of § 25.571. For structural elements in systems, (with the exception of the main structural elements in landing gear, the horizontal stabilizer surface, and other control surfaces, including high lift surfaces), meeting the damage tolerance requirement of § 25.571 by itself is not sufficient to justify the assumption that a single failure will not occur. This is because single failure of structural elements can occur due to causes other than those addressed by § 25.571. For specific guidance related to structural elements in flight control systems, refer to Policy Statement No. PS- ANM-25-12 or the most recent FAA policy.
1.2.2.11 Section 25.1309 requirements are applicable to the electrical and
electronic systems covered under § 25.1316, Electrical and electronic system lightning protection, and § 25.1317, High-Intensity Radiated Fields (HIRF) Protection. Sections 25.1316 and 25.1317 provide standards for those systems that are considered critical for continued safe flight and landing. Refer to AC 20-136, Aircraft Electrical and Electronic System Lightning Protection, and AC 20-158, The Certification of Aircraft Electrical and Electronic Systems for Operation in the HIRF Environment, for guidance on the safety assessment of electrical and electronic systems for lightning and HIRF environments, respectively.