MOC SC-VTOL
Means of Compliance with SC-VTOL — Batch 1
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 1 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Initial final means of compliance with SC-VTOL. Later final MoC batches supplement or amend specific provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: db12643dc7ceea42b40a49945615bf06cf39e0f2e6743090241a00eafca7a8a2
Means of Compliance with the Special Condition VTOL
Doc. No: MOC SC-VTOL Issue: 2 Date: 12 May 2021
Fail/Pass Criteria; when submitted to the Lightning Environment, it
could be acceptable that equipment is/are subject to adverse effect; provided that the Level A function is maintained at the aircraft level and all the Equipment/System, required in normal operation, recover manually or automatically, in a timely manner, this function after the threat.
(ii) For Level B Systems
Conduct Equipment/System testing using the following categories:
(A) According to the VTOL aircraft primary structure and wiring type, choose the
appropriate Category/Waveform at Level 2 in EUROCAE ED-14G 22. (B) Fail/Pass Criteria; when submitted to the Lightning Environment, it could be
acceptable that redundant equipment is/are subject to adverse effects, provided that the Level B function is recovered manually or automatically, in a timely manner, after the threat.
IEL Group III
(i) For Level A Non-Display Systems:
(A) Follow the AMC 20-136; or (B) Determine the aircraft Actual Transient Level (ATL) (by test, analysis, combination of
both or by similarity); and (C) Conduct Equipment/System testing using the following categories:
According to the VTOL aircraft primary structure and wiring type,
choose the appropriate Category/Waveform at Level 3 or 4 in EUROCAE ED-14G section 22. Fail/Pass Criteria; when submitted to the Lightning Environment, it
could be acceptable that equipment is/are subject to adverse effect, provided that the Level A function is maintained at the aircraft level and all the Equipment/Systems that are required in normal operation, recover manually or automatically, in a timely manner, this function after the threat. Verify the positive margin between the default levels applied during the
Equipment/System testing (EDTL as defined in (a)) and the Transient Control Level (TCL, maximum expected aircraft ATLs). If a positive margin is not established, corrective measures should be implemented in line with AMC 20-136.
(ii) For level A Display Systems:
Conduct Equipment/System testing using the following categories:
(A) For VTOL aircraft with primarily metal structure, EUROCAE ED-14G section 22
category A3J3L3. (B) For VTOL aircraft with primarily carbon fibre, fiberglass or non-conductive material
structure, EUROCAE ED-14G section 22 category B3K3L3.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source