MOC SC-VTOL
Means of Compliance with SC-VTOL — Batch 1
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 1 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Initial final means of compliance with SC-VTOL. Later final MoC batches supplement or amend specific provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: db12643dc7ceea42b40a49945615bf06cf39e0f2e6743090241a00eafca7a8a2
Means of Compliance with the Special Condition VTOL
Doc. No: MOC SC-VTOL Issue: 2 Date: 12 May 2021
Downward – 20 g. Rearward – 1.5 g.
(c) For energy storage systems located above or adjacent the crew or passenger compartment that, if
loosened, could injure an occupant in an emergency landing:
Upward – 1.5 g. Forward – 12 g. Sideward – 6 g. Downward – 12 g. Rearward – 1.5 g.
(d) For energy storage systems in other areas:
Upward – 1.5 g. Forward – 4 g. Sideward – 2 g. Downward – 4 g.
5. Energy storage system isolation means.
(a) For liquid or gaseous fuel systems, self-sealing isolation means should be installed unless hazardous
relative motion of energy storage system components to each other or to local aircraft structure is demonstrated to be extremely improbable or unless other means are provided. (b) The isolations means, such as a fuses, couplings or equivalent devices should be installed where
structural deformation could lead to a hazard to the occupants due to high energy release or release of harmful amount of fluids or gases. (c) For liquid or gaseous fuel systems, the design and construction of the isolation means for fuel tank to
fuel line connections, fuel tank to fuel tank interconnects, and other points in the fuel system should incorporate the following design features:
the load necessary to separate a breakaway coupling should be between 25 and 50% of the minimum ultimate failure load (ultimate strength) of the weakest component in the fuel- carrying line. The separation load should in no case be less than 1334 N (300 lb), regardless of the size of the fuel line; a breakaway coupling should separate whenever its ultimate load (as defined in sub- paragraph 5(c)(1)) is applied in the failure modes most likely to occur; all breakaway couplings should incorporate design provisions to visually ascertain that the coupling is locked together (leak-free) and is open during normal installation and service; all breakaway couplings should incorporate design provisions to prevent uncoupling or unintended closing due to operational shocks, vibrations, or accelerations; and no breakaway coupling design may allow the release of liquid or gaseous fuel once the coupling has performed its intended function.
(d) For electrical energy storage systems:
During a crash landing in which structural damage could lead to the release of high energy, an isolation means should ensure that no energy can be released from the energy storage system which could lead to serious injury to occupants or persons on ground. Its activation should be:
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source