MOC SC-VTOL
Means of Compliance with SC-VTOL — Batch 1
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 1 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Initial final means of compliance with SC-VTOL. Later final MoC batches supplement or amend specific provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: db12643dc7ceea42b40a49945615bf06cf39e0f2e6743090241a00eafca7a8a2
Means of Compliance with the Special Condition VTOL
Doc. No: MOC SC-VTOL Issue: 2 Date: 12 May 2021
(i) automatic, unless this is demonstrated to be impractical, in which case other means
acceptable to EASA may be employed. (ii) indicated to the flight crew and rescue personnel.
A manual isolation means has to be safely accessible for the rescue personnel and be clearly marked.
(e) All individual isolation means, such as fuses, emergency stop, breakaway couplings, coupling fuel feed
systems, or equivalent means should be designed, tested, installed and maintained so that inadvertent activation in flight is minimised to the maximum extent practicable. It should be ensured that the isolation means are not degrading beyond an acceptable level in accordance with the reliability requirements for systems and the fatigue requirements for structural installations. (f) Alternatively, for gaseous or liquid fuels, equivalent means to the use of breakaway couplings should
not create a survivable impact-induced load on the fuel line to which it is installed greater than 25 to 50% of the ultimate load (strength) of the weakest component of the line and should comply with the fatigue requirements of CS 27.571 Amdt. 6 without leaking.
6. Frangible or deformable structural attachments.
(a) Frangible or locally deformable attachments of energy storage system components to local aircraft
structure should be used unless hazardous relative motion of energy storage system components to local aircraft structure is demonstrated to be extremely improbable in an otherwise survivable impact,. (b) The attachment of energy storage system components to local aircraft structure, whether frangible or
locally deformable, should be designed such that separation or relative local deformation of the attachment of energy storage system components will occur without rupture or local tear-out of energy storage system components that will could cause leakage or high energy release. (c) The load required to separate a frangible energy storage system components attachment from its
support structure, or to deform a locally deformable attachment relative to its support structure, should be between 25% and 50% of the minimum ultimate load (ultimate strength) of the weakest component in the attached system. In no case should the load be less than 1330 N (300 lbs). (d) A frangible or locally deformable energy storage system components attachment should separate or
locally deform as intended whenever its ultimate load (as defined in sub-paragraph 6(c)) is applied in the modes most likely to occur. (e) All frangible or locally deformable energy storage system components attachments should comply with
the fatigue requirements of CS 27.571 Amdt. 6.
7. Separation of flammable fluids or gases and ignition sources.
To provide maximum crash resistance, flammable fluids or gases should be located as far as practicable from all occupiable areas and from all potential ignition sources.
8. Other basic mechanical design criteria.
Battery system components, electrical wires, and electrical devices should be designed, constructed and installed, as far as practicable, to be crash resistant.
9. Rigid or semi-rigid fuel tanks.
Rigid or semi-rigid fuel tank or bladder walls should be impact and tear resistant.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.