MOC SC-VTOL
Means of Compliance with SC-VTOL — Batch 1
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 1 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Initial final means of compliance with SC-VTOL. Later final MoC batches supplement or amend specific provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: db12643dc7ceea42b40a49945615bf06cf39e0f2e6743090241a00eafca7a8a2
Means of Compliance with the Special Condition VTOL
Doc. No: MOC SC-VTOL Issue: 2 Date: 12 May 2021
MOC VTOL.2325(b)(1) and (b)(2) Fire Protection: fire extinguishers and design of interiors
1. Category Basic
(a) Fire Extinguishers: CS 23.851(a), (b)(1), (c) Amdt. 4 are accepted as a means of compliance (b) Compartment interiors: CS 27.853 Amdt. 6 is accepted as a means of compliance. (c) Cargo and baggage compartment: CS 27.855 Amdt. 6 is accepted as a means of compliance.
2. Category Enhanced
For Category Enhanced the means of compliance accepted for Category Basic should be completed with the following provisions:
(a) Compartment interiors: CS 29.853(a), (b) and (d) Amdt. 7 are accepted as a means of compliance. (b) Baggage compartment:
A baggage compartment that is located where the presence of a fire would not easily be discovered by a pilot while at his station should:
Have ceiling and sidewall liners and floor panels constructed of materials that have been subjected to and meet the 45° angle test of Appendix F to CS-23 Amdt. 4. The flame should not penetrate (pass through) the material during application of the flame or subsequent to its removal. The average flame time after removal of the flame source should not exceed 15 s, and the average glow time should not exceed 10 s. The compartment should be constructed to provide fire protection that is not less than that required of its individual panels; or Be constructed and sealed to contain any fire within the compartment or have a device to ensure detection of fires or smoke by a crew member while at his station and to prevent the accumulation of harmful quantities of smoke, flame, extinguishing agents, and other noxious gases in any crew or passenger compartment.
MOC VTOL.2335 Lightning Protection
(a) In order to demonstrate that the exposure to lightning is “unlikely”, the same operational limitations as
defined in MOC VTOL.2515 “Electrical and electronic system lightning protection” are accepted. (b) CS 27.610 Amdt. 6 is accepted as a means of compliance. (c) As an alternative to CS 27.610 Amdt. 6, paragraph 17.1 of ASTM F3061/F3061M-19 “Standard Specification
for Systems and Equipment in Small Aircraft” is also accepted as a means of compliance.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source