EASA Means of ComplianceFinal — current published edition checked

MOC SC-VTOL

Means of Compliance with SC-VTOL — Batch 1

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 1 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Initial final means of compliance with SC-VTOL. Later final MoC batches supplement or amend specific provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: db12643dc7ceea42b40a49945615bf06cf39e0f2e6743090241a00eafca7a8a2

Source page 35 · PDF page 35

Means of Compliance with the Special Condition VTOL

Doc. No: MOC SC-VTOL Issue: 2 Date: 12 May 2021

Voting mechanisms, Protections priorities (e.g. entry/exit logic conditions not symmetrical), Determination of critical scenario for multiple failures.

The validation strategy should include but should not be limited to operational scenarios. The determination that an adequate level of validation of the FCL design has been achieved should be based on engineering judgment.

(d) Documentation to be provided

The applicant should prepare a checklist with a defined set of test cases based on experience, and provide the FCL Validation methodology and strategy for verification by EASA.

(e) Auditing

The Applicant should perform adequate auditing and EASA may define a related Level of Involvement in such audits.

Compliance should be shown in conjunction with the following requirements: VTOL.2135, VTOL.2145, VTOL.2500 and VTOL.2510.

MOC VTOL.2300(a)(1) Function and operation of Fly-by-Wire flight control system

(a) Flight crew awareness of the modes of operation

If the design of the flight control system has multiple modes of operation (e.g. hover, transition, cruise modes) and/or includes degraded modes following failures, a means should be provided to indicate to the crew any mode that significantly changes or degrades the handling or operational characteristics of the aircraft. The sub-modes of operation (both in nominal and degraded mode) and the transition between them should be smooth, and should be evaluated to determine whether or not they are intuitive. If these sub-modes or the transition between them are not intuitive, an indication to the flight crew may be required. This indication may be different from the classic “failure alerting”. In case of several flight control modes, limitations should be clearly annunciated and the definition of a Training Area of Special Emphasis (TASE) in the Flight Crew Data (FCD) may need to be established during the certification of the Operational Suitability Data (OSD).

Compliance should be shown in conjunction with other paragraphs (such as VTOL.2445), where failures could lead to flight control mode degradation.

(b) Flight envelope protection

If Flight Envelope Protection (FEP) features are implemented, then these should follow the following principles:

Onset characteristics of each envelope protection feature should be smooth, appropriate to the phase of flight and type of manoeuvre; and not be in conflict with the ability of the pilot to satisfactorily change the aircraft flight path (e.g. speed, attitude) within the approved flight envelope.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.