CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
Figure 2: Factor of safety at the time of occurrence
For continuation of the flight following in-flight thrust reversal, considering any appropriate reconfiguration and flight limitations, the following apply:
7.b.(1) Static strength should be determined for loads derived from the following conditions
at speeds up to VC, or the speed limitation prescribed for the remainder of the flight:
(i) 70% of the limit flight manoeuvre loads; and separately
(ii) the discrete gust conditions specified in CS 25.341(a) (but using 40% of the gust velocities specified for VC).
7.b.(2) For the aeroplane with high lift devices deployed, static strength should be
determined for loads derived from the following conditions at speeds up the appropriate flap design speed, or any lower flap speed limitation prescribed for the remainder of the flight:
(i) A balanced manoeuvre at a positive limit load factor of 1.4; and separately
(ii) the discrete gust conditions specified in CS 25.345(a)(2) (but using 40% of the gust velocities specified).
7.b.(3) For static strength substantiation, each part of the structure must be able to withstand
the loads specified in sub-paragraph 7.b.(1) and 7.b.(2) of this paragraph, multiplied by a factor of safety depending on the probability of being in this failure state. The factor of safety is defined in Figure 3, below.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source