CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
(2) The capacity of each required built-in fire extinguishing system must be adequate for any fire likely to occur anywhere in the compartment where used, considering the volume of the compartment and the ventilation rate. (see AMC 25.851(b)).
(c) Fire-extinguishing agents
(See AMC 25.851(c))
(1) Fire classes against which fire-extinguishing agents may be employed are:
— Class A: Fires involving ordinary combustible materials, such as wood, cloth, paper,
rubber and plastics;
— Class B: Fires involving flammable liquids, petroleum oils, greases, tars, oil base paints,
lacquers, solvents, alcohols and flammable gases;
— Class C: Fires involving energised electrical equipment where the use of an extinguishing
agent that is electrically non-conductive is important.
[Amdt 25/4] [Amdt 25/8] [Amdt 25/12] [Amdt 25/18]
AMC 25.851(a) Hand fire extinguishers
1 Each extinguisher should be readily accessible and mounted so as to facilitate quick removal from its mounting bracket.
2 Unless an extinguisher is clearly visible, its location should be indicated by a placard or sign having letters of at least 9.5 mm (0·375) inches in height on a contrasting background. Appropriate symbols may be used to supplement such a placard or sign.
[Amdt 25/12]
AMC 25.851(a)(1) Hand fire extinguishers
1 The number and location of hand fire extinguishers should be such as to provide adequate availability for use, account being taken of the number and size of the passenger compartments and the location of toilets, galleys, etc. These considerations may result in the number being greater than the minimum prescribed.
2 Where only one hand extinguisher is required it should be located at the cabin crew member station, where provided, otherwise near the main entrance door.
3 Where two or more hand extinguishers are required and their location is not otherwise dictated by consideration of paragraph 1 above, an extinguisher should be located at each end of the cabin and the remainder distributed throughout the cabin as evenly as is practicable.
[Amdt 25/12]