CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
POWERPLANT FIRE PROTECTION
CS 25.1181 Designated fire zones: regions included
(See AMC 25.1181.)
(a) Designated fire zones are –
(1) The engine power section;
(2) The engine accessory section;
(3) Any complete powerplant compartment in which no isolation is provided between the engine power section and the engine accessory section;
(4) Reserved.
(5) Any fuel-burning heater and other combustion equipment installation described in CS 25.859;
(6) The compressor and accessory sections of turbine engines; and
(7) Combustor, turbine, and tailpipe sections of turbine engine installations that contain lines or components carrying flammable fluids or gases.
(b) Each designated fire zone must meet the requirements of CS 25.863, 25.867, 25.869, and 25.1185 to 25.1203
AMC 25.1181 Designated fire zones
1 ISO 2685, (15 JULY 1992) ‘Aircraft – Environmental conditions and test procedures for airborne equipment – Resistance to fire in designated fire zones’, gives test conditions and methods of demonstrating compliance with the ‘Fire-resistant’ and ‘Fireproof’ requirements.
2 Tests to demonstrate compliance with the standard grades of resistance to fire may not be necessary if similarity can be shown with other components which have been tested in accordance with this standard.
3 For example, materials which are considered satisfactory for use in firewalls without being subjected to fire tests include –
a. Stainless steel sheet 0·4 mm (0·016 in) thick;
b. Mild steel sheet protected against corrosion 0·45 mm (0·018 in) thick; and
c. Titanium sheet 0·45 mm (0·018 in) thick.
CS 25.1182 Nacelle areas behind firewalls, and engine pod attaching structures containing flammable fluid lines
(a) Each nacelle area immediately behind the firewall, and each portion of any engine pod attaching structure containing flammable fluid lines, must meet each requirement of CS 25.1103(b),
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source