EASA Certification Specifications with AMCFinal — current published edition checked

CS-25

Large Aeroplanes

Amendment 28; corrected 20 November 2025 Source checked 2026-11-28

Scope, source and reading notes

Complete official CS-25 Amendment 28, including AMC and appendices.

Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007

Source page 1040 · PDF page 1040

CS 25.1391 Minimum intensities in the horizontal plane of forward and rear position lights

Each position light intensity must equal or exceed the applicable values in the following table:

Angle from right or left of longitudinal

Intensity candela (candles)

Dihedral angle (light included)

axis, measured from dead ahead

L and R (forward red and green)

41 (40) 31 (30)

A (rear white)

0o to 10 o 10 o to 20 o 20 o to 110 o 110 o to 180 o

5 20

CS 25.1393 Minimum intensities in any vertical plane of forward and rear position lights

Each position light intensity must equal or exceed the applicable values in the following table:

Angle above or below the horizontal plane: Intensity 0° 1·00 I 0° to 5° 0·90 I 5° to 10° 0·80 I 10° to 15° 0·70 I 15° to 20° 0·50 I 20° to 30° 0·30 I 30° to 40° 0·10 I 40° to 90° 0·05 I

CS 25.1395 Maximum intensities in over-lapping beams of forward and rear position lights

No position light intensity may exceed the applicable values in the following table, except as provided in CS 25.1389(b)(3):

Overlaps Maximum intensity Area A candela (candles) Area B candela (candles) Green in dihedral angle L 10 1 Red in dihedral angle R 10 1 Green in dihedral angle A 5 1 Red in dihedral angle A 5 1 Rear white in dihedral angle L 5 1 Rear white in dihedral angle R 5 1 Where –

(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and

(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.

View figures, tables and original page layoutOriginal source page Source page 1040 · PDF page 1040 of CS-25

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-152A

Listed as related material by

Source-backed
Evidence and scope

AMC 20-152A §8(a)(2)

Lists CS-25 without an amendment or specific paragraph.

Family reference; does not select a certification basis.

Supporting source

Copy reference

Select and copy the citation below.