CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
(5) The fuel temperature must be at least 43.3°C (110°F).
(b) The test prescribed in sub-paragraph (a) of this paragraph may be performed in flight or on the ground under closely simulated flight conditions. If a flight test is performed in weather cold enough to interfere with the proper conduct of the test, the fuel tank surfaces, fuel lines, and other fuel system parts subject to cold air must be insulated to simulate, insofar as practicable, flight in hot weather.
CS 25.963 Fuel tanks: general
(See AMC 25.963)
(a) Each fuel tank must be able to withstand, without failure, the vibration, inertia, fluid and structural loads that it may be subjected to in operation. (See AMC 25.963(a).)
(b) Flexible fuel tank liners must be approved or must be shown to be suitable for the particular application.
(c) Integral fuel tanks must have facilities for interior inspection and repair.
(d) Fuel tanks must, so far as it is practicable, be designed, located and installed so that no fuel is released in or near the fuselage or near the engines in quantities sufficient to start a serious fire in otherwise survivable emergency landing conditions, and:
(1) Fuel tanks must be able to resist rupture and to retain fuel under ultimate hydrostatic design conditions in which the pressure P within the tank varies in accordance with the formula:
𝑃= 𝐾𝜌𝑔𝐿
where:
P = fuel pressure in Pa (lb/ft2) at each point within the tank
L = a reference distance in m (ft) between the point of pressure and the tank farthest boundary in the direction of loading.
= typical fuel density in kg/m3 (slugs/ft3)
g = acceleration due to gravity in m/s2 (ft/s2)
K = 4.5 for the forward loading condition for fuel tanks outside the fuselage contour
K = 9 for the forward loading condition for fuel tanks within the fuselage contour
K = 1.5 for the aft loading condition
K = 3.0 for the inboard and outboard loading conditions for fuel tanks within the fuselage contour
K = 1.5 for the inboard and outboard loading conditions for fuel tanks outside of the fuselage contour
K = 6 for the downward loading condition
K = 3 for the upward loading condition
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source