CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
OIL SYSTEM
CS 25.1011 General
(a) Each engine must have an independent oil system that can supply it with an appropriate quantity of oil at a temperature not above that safe for continuous operation.
(b) The usable oil capacity may not be less than the product of the endurance of the aeroplane under critical operating conditions and the approved maximum allowable oil consumption of the engine under the same conditions, plus a suitable margin to ensure system circulation.
CS 25.1013 Oil tanks
(a) Installation. Each oil tank installation must meet the requirements of CS 25.967.
(b) Expansion space. Oil tank expansion space must be provided as follows:
(1) Each oil tank must have an expansion space of not less than 10% of the tank capacity.
(2) Each reserve oil tank not directly connected to any engine may have an expansion space of not less than 2% of the tank capacity.
(3) It must be impossible to fill the expansion space inadvertently with the aeroplane in the normal ground attitude.
(c) Filler connection. Each recessed oil tank filler connection that can retain any appreciable quantity of oil must have a drain that discharges clear of each part of the aeroplane. In addition each oil tank filler cap must provide an oil-tight seal.
(d) Vent. Oil tanks must be vented as follows:
(1) Each oil tank must be vented from the top part of the expansion space so that venting is effective under any normal flight condition.
(2) Oil tank vents must be arranged so that condensed water vapour that might freeze and obstruct the line cannot accumulate at any point.
(e) Outlet. There must be means to prevent entrance into the tank itself, or into the tank outlet, of any object that might obstruct the flow of oil through the system. No oil tank outlet may be enclosed by any screen or guard that would reduce the flow of oil below a safe value at any operating temperature. There must be a shut-off valve at the outlet of each oil tank, unless the external portion of the oil system (including the oil tank supports) is fireproof.
(f) Flexible oil tank liners. Each flexible oil tank liner must be approved or must be shown to be suitable for the particular application.
CS 25.1015 Oil tank tests
Each oil tank must be designed and installed so that –
(a) It can withstand, without failure, each vibration, inertia, and fluid load that it may be subjected to in operation; and
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source