CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
(5) When the specimen is to be injected, the radiation doors are opened, the specimen is injected into the environmental chamber, and the radiation doors are closed behind the specimen.
(6) Reserved.
(7) Injection of the specimen and closure of the inner door marks time zero. A continuous record of the thermopile output with at least one data point per second must be made during the time the specimen is in the environmental chamber.
(8) The test duration time is five minutes.
(9) A minimum of three specimens must be tested.
(f) Calculations
(1) The calibration factor is calculated as follows:
× 𝑃−𝑃𝑉
𝐾ℎ= (𝐹1 −𝐹0)
𝑚𝑜𝑙𝑒 × 273
760 × 𝑚𝑜𝑙𝑒 𝐶𝐻4𝑆𝑇𝑃
22 ∙41
𝑇𝑎
(𝑉1 −𝑉2) × (210 ∙8 −22)𝑘𝑐𝑎𝑙
× 𝑊𝐴𝑇𝑇𝑚𝑖𝑛
. 01433 𝑘𝑐𝑎𝑙× 𝑘𝑊 1000𝑊
F0 = Flow of methane at baseline (1pm)
F1 = Higher preset flow of methane (1pm)
V0 = Thermopile voltage at baseline (mv)
V1 = Thermopile voltage at higher flow (mv)
Ta = Ambient temperature (K)
P = Ambient pressure (mm Hg)
Pv = Water vapour pressure (mm Hg)
(2) Heat release rates may be calculated from the reading of the thermopile output voltage at any instant of time as:
𝐻𝑅𝑅= 𝑉𝑚−𝑉𝑏 ∙02323𝑚2 × 𝐾ℎ
HRR = Heat Release Rate kW/m2
Vm = Measured thermopile voltage (mv)
Vb = Baseline voltage (mv)
Kh = Calibration Factor (kW/mv)
(3) The integral of the heat release rate is the total heat release as a function of time and is calculated by multiplying the rate by the data sampling frequency in minutes and summing the time from zero to two minutes.
(g) Criteria. The total positive heat release over the first two minutes of exposure for each of the three or more samples tested must be averaged, and the peak heat release rate for each of the samples must be averaged. The average total heat release must not exceed 65 kilowatt-minutes per square metre, and the average peak heat release rate must not exceed 65 kilowatts per square metre.
(h) Report. The test report must include the following for each specimen tested:
(1) Description of the specimen.