CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
— Kuchta, Joseph M., Summary of Ignition Properties of Jet Fuels and Other Aircraft
Combustible Fluids, Technical Report AFAPL-TR-75-70. Springfield, VA: U.S. Department of Commerce, 1975
3. Definitions
— Autogenous Ignition (Auto-Ignition) Temperature (AIT). The minimum temperature at
which an optimised flammable vapour and air mixture will spontaneously ignite when heated to a uniform temperature in a normal atmosphere without an external source of ignition, such as a flame or spark.
— Flammability Limit. The highest and lowest concentration of fuel-in-air-by-volume per cent
that will sustain combustion. A fuel-to-air mixture below the lower limit is too lean to burn, while a mixture above the upper limit is too rich to burn. The flammability limit varies with altitude and temperature and is typically presented on a temperature-versus-altitude plot.
— Flash Point. The minimum temperature at which a flammable liquid will produce flammable
vapour at sea level ambient pressure.
— Flame Holding. The ability of a flame arrestor to halt the propagation of a flame front
through a passage.
— Ignition Source. A source of sufficient energy to initiate combustion of a fuel-air mixture.
Hot surfaces that can exceed the auto-ignition temperature of the flammable vapour under consideration are considered to be ignition sources. Electrical arcs, electrical sparks, and friction sparks are also considered to be ignition sources if sufficient energy is released to initiate combustion.
— Stoichiometric Ratio. The ratio of fuel to air corresponding to the condition in which the
available amounts of fuel and oxygen completely react with each other, thereby resulting in combustion products that contain neither fuel nor oxygen.
4. Acceptable means of compliance
Acceptable means of compliance with CS 25.975(a)(7) include:
— flame arrestors in the fuel tank vents that prevent flame propagation into the fuel tank
(see paragraph 5 of this AMC);
— fuel tank inerting systems that exceed the basic requirements of CS 25.981 and prevent fuel
tank explosions* (see paragraph 7.1 of this AMC);
— fuel tank pressurisation systems or features of the system that result in a closed vent
system and that are effective in preventing a fuel tank explosion during all operating conditions (e.g. taxiing, take-off, landing, refuelling, etc.) and post-crash fire conditions (see paragraph 7.2 of this AMC); and
— fuel tank or vent system fire suppression systems that prevent a fuel tank explosion with a
fire present at the fuel tank vent outlet for the required 2 minutes and 30 seconds (see paragraph 7.3 of this AMC).
* Fuel tank inerting systems that meet CS 25.981 would not necessarily be adequate for demonstrating compliance with CS 25.975 because CS 25.981 does not require the fuel tank ullage to be fully inert at all times. If inerting is used as the means of compliance with CS 25.975, the inerting system must be effective
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source