CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
A.16 PRACTICALITY.
A balance of the available means, economic viability, and proportional benefit to safety.
A.17 RELIABLE DESIGN.
A reliable design is a design that provides lightning protection features that are not anticipated to degrade during the life of the aeroplane.
A.18 RELIABLE FAULT TOLERANCE.
A fault-tolerant fuel system design is a design that precludes ignition sources in the fuel system even when a fault is present; ‘reliable’ means that the system has the ability to maintain the effectiveness of the protection features over the service life of the individual aeroplane.
A.19 REMOTE.
Refer to the definition provided in Section 7 of AMC 25.1309 (qualitative and quantitative terms).
A.20 SYSTEMS.
Systems include fuel, mechanical, hydraulic, electrical, and electrical wiring interconnection system (EWIS) components that penetrate, are located within, or connected to the fuel tanks.
Appendix B. Section 4 Examples
B.1 EXAMPLES FOR PARAGRAPH 4.1.2.1
The design elements or features for which providing fault-tolerant prevention of lightning ignition sources should be practical include the:
1. Installation of rivets and bolts in aluminium structures that are well bonded through processes that ensure the fastener/hole fit, fastener and hole quality, and installation practices;
2. Installation of bolts in composite structures that are well bonded through processes that ensure control of the fastener/hole fit, fastener and hole quality, and installation practices and with additional design features to distribute current, such as foil or mesh at the material surface; and the
3. Installation of lightning protective sealant or cap seals over fastener heads/ends located inside fuel tanks, where necessary.
B.2 EXAMPLES FOR PARAGRAPH 4.1.2.2
The design features or failures for which providing fault-tolerant prevention of lightning ignition sources could be impractical include:
1. Fatigue cracking within structural elements such as spars, skins, stringers, and ribs. Typically, material controls, manufacturing controls, established material allowables, design margins, and life-cycle tests make the occurrence of significant cracking rare.
2. Failures of fasteners highly loaded in tension that lead to separation of the fasteners or parts of the fasteners from the hole, or gapping of the heads or nuts of the fasteners, and the
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source