CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
— EUROCAE document ED-91A (Aircraft Lightning Zoning) or the equivalent SAE ARP5414B.
— EUROCAE document ED-105A (Aircraft Lightning Test Methods) or the equivalent SAE ARP
5416A.
— EUROCAE document ED-113 (Aircraft Lightning Direct Effects Certification) or the
equivalent SAE ARP 5577.
3 Protection against the Accumulation of Static Charges
3.1 General. All items, which by the accumulation and discharge of static charges may cause a danger of electrical shock, ignition of flammable vapours or interference with essential equipment (e.g. radio communications and navigational aids) should be adequately bonded to the main earth systems.
3.2 Intermittent Contact. The design should be such as to ensure that no fortuitous intermittent contact can occur between metallic and/or metallized parts.
3.3 High Pressure Refuelling and Fuel Transfer. Where provision is made for high pressure refuelling and/or for high rates of fuel transfer it should be established, by test, or by consultation with the appropriate fuel manufacturers, that dangerously high voltages will not be induced within the fuel system. If compliance with this requirement involves any restriction on the types of fuel to be used or on the use of additives, this should be established.
3.3.1 With standard refuelling equipment and standard aircraft turbine fuels, voltages high
enough to cause sparking may be induced between the surface of the fuel and the metal parts of the tank at refuelling flow velocities above approximately 7 meters/second (23 feet/second). These induced voltages may be increased by the presence of additives and contaminants (e.g. anti-corrosion inhibitors, lubricating oil, free water), and by splashing or spraying of the fuel in the tank.
3.3.2 The static charge can be reduced as follows:
a. By means taken in the refuelling equipment such as increasing the diameter of refuelling lines and designing filters to give the minimum of electrostatic charging, or
b. By changing the electrical properties of the fuel by the use of anti-static additives and thus reducing the accumulation of static charge in the tank to negligible amount.
3.3.3 The critical refuelling rates are related to the aeroplane refuelling installations, and the
designer should seek the advice of fuel suppliers on this problem.
4 Primary and Secondary Bonding Paths.
(Reference : CS 25.581; 25.899, 25.954; 25.1316; 25.1353; 25.1360.)
4.1 Primary bonding paths are those paths which are required to carry lightning discharge currents. These paths should be of as low an electrical impedance as is practicable. Secondary bonding paths are those paths provided for other forms of bonding.
4.2 Where additional conductors are required to provide or supplement the inherent primary bonding paths provided by the structure or equipment, then the cross-sectional area of such