Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
TABLE 2-1. TERMS AND SYMBOLS
Dimensionless
SYMBOL DESCRIPTION UNITS CONSISTENT WITH EQUATIONS C(t) Halon 1301 concentration by volume at time “t.” = VHalon 1301 / V
Cubic metre - m3 (Cubic feet - ft3)
VHalon 1301 Volume of Halon 1301 in cargo compartment. Cubic metre - m3 (Cubic feet - ft3) V Cargo compartment free volume (i.e., volume not occupied by cargo). = 1 - ( Vcargo / Vempty )
Vcargo Cargo volume. Cubic metre - m3 (Cubic feet - ft3) Vempty Empty cargo compartment volume. Cubic metre - m3 (Cubic feet - ft3) T Time. Minutes – Min E Cargo compartment leakage rate. Cubic metre per minute - m3/min (Cubic feet per minute - ft3/min) S Specific volume of Halon 1301. Cubic metre per kilogram m3/kg (cubic feet per pounds(mass) ft3/lbm) R Halon 1301 flow rate. Kilogram per minute kg/min (pounds(mass) per minute lbm/min) 3. HALON 1301 CONCENTRATION LEVEL MODEL.
Cargo compartment fire extinguishing systems generally use a combination of one or two types of Halon 1301 discharge methods. One type rapidly releases all of the fire extinguishing agent from one or more pressurised bottles into the cargo compartment. This type of discharge method is commonly known as a high rate discharge or ‘dump’ system.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source