EASA Certification Specifications with AMCFinal — current published edition checked

CS-25

Large Aeroplanes

Amendment 28; corrected 20 November 2025 Source checked 2026-11-28

Scope, source and reading notes

Complete official CS-25 Amendment 28, including AMC and appendices.

Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007

Source page 525 · PDF page 525

1. Z is the distance factor obtained from Table 1 below;

2. hletter is the overall height of each letter – which should be at least of 25 mm (1 inch) high;

3. hsymbol is the overall height of the white symbolic element incorporating the green ‘running man’ – which should be at least 40 mm (1.6 inches) high;

4. xsign is the overall area of the sign; and

5. D1, D2, hletter and hsymbol have the same units, and xsign is in the same squared units as D1, D2, hletter and hsymbol.

Note 1: In the case of dual-language text based emergency exit signs, only the English text is to be considered when selecting hletter for use in the above formula. However, in determining the area of the sign (xsign) for use in the above formula, the actual area may be used

Examples of acceptable designs of symbolic exit signs

CS 25.811(d)(1) (emergency exit locator sign)

CS 25.811(d)(2) (emergency exit marking sign)

CS 25.811(d)(3) (emergency exit sign on bulkhead or divider)

Table 1: Z factor to be used for text based and symbolic emergency exit signs

Mean luminance of white contrast

Distance factor Z

colour candela/m2 (ft-L)

 1.27 candela/m2 (0.37 ft-L)

100 150

 10 candela/m2 (2.92 ft-L)

 30 candela/m2 (8.76 ft-L) 175

 80 candela/m2 (23.35 ft-L) 200

 200 candela/m2 (58.37 ft-L) 215

 500 candela/m2 (145.93 ft-L) 230

Minimum size - emergency exit signs required by CS 25.811(d)(2)

For an emergency exit sign required by CS 25.811(d)(2), any sign using English letters of at least 25 mm (1 inch) height, or a white symbolic element (i.e. that part incorporating the green ‘running man’) of at least 40 mm (1.6 inches), with an overall area of at least 64.5 cm2 (10 square inches) will be acceptable.

Supplementary directional arrows

View figures, tables and original page layoutOriginal source page Source page 525 · PDF page 525 of CS-25

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-152A

Listed as related material by

Source-backed
Evidence and scope

AMC 20-152A §8(a)(2)

Lists CS-25 without an amendment or specific paragraph.

Family reference; does not select a certification basis.

Supporting source

Copy reference

Select and copy the citation below.