EASA Certification Specifications with AMCFinal — current published edition checked

CS-25

Large Aeroplanes

Amendment 28; corrected 20 November 2025 Source checked 2026-11-28

Scope, source and reading notes

Complete official CS-25 Amendment 28, including AMC and appendices.

Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007

Source page 217 · PDF page 217

to account for the probability of the aeroplane flying at any given altitude during its service lifetime.

It should be noted that the reference gust velocity is comprised of two components, a root-mean-square (RMS) gust intensity and a peak to RMS ratio. The separation of these components is not defined and is not required for the linear aeroplane analysis. Guidance is provided in Paragraph 8.d. of this AMC for generating a RMS gust intensity for a non-linear simulation.

(2) Continuous Turbulence Response. For linear aeroplane systems, the solution for the response to continuous turbulence may be performed entirely in the frequency domain, using the RMS response. is defined in CS 25.341(b)(2) and is repeated here in modified notation for load quantity i, where:

∞

1 2 ⁄

𝐴̅𝑖= [∫|ℎ𝑖(𝛺)|2

𝛷𝐼(𝛺)𝑑𝛺]

0

or

∞

1 2 ⁄

∗(𝑖𝛺)𝑑𝛺]

𝐴̅𝑖= [∫𝛷𝐼(𝛺)

ℎ𝑖(𝑖𝛺)ℎ𝑖

0

In the above expression ΦI(Ω) is the input Von Kármán power spectrum of the turbulence and is defined in Paragraph 5.c.(1) of this AMC, hi(iΩ) is the transfer function relating the output load quantity, i, to a unit, harmonically oscillating, one- dimensional gust field, and the asterisk superscript denotes the complex conjugate. When evaluating Āi, the integration should be continued until a converged value is achieved since, realistically, the integration to infinity may be impractical. The design limit load, PLi, is then defined as:

𝑃𝐿𝑖= 𝑃(1−𝑔)𝑖± 𝑃𝑙𝑖

= 𝑃(1−𝑔)𝑖± 𝑈𝜎 𝐴𝑖

where Uσ is defined in Paragraph 5.c.(1) of this AMC, and P(1-g)i is the 1-g steady state value for the load quantity, i, under consideration. As indicated by the formula, both positive and negative load responses should be considered when calculating limit loads.

Correlated (or equiprobable) loads can be developed using cross-correlation coefficients, ρij, computed as follows:

∫ 𝛷𝐼(𝛺)𝑟𝑒𝑎𝑙[ℎ𝑖(𝑖𝛺)ℎ∗

𝑗(𝑖𝛺)] 𝑑𝛺 ∞ 0

𝜌𝑖𝑗=

A𝑖 A𝑗

where, ‘real[...]’ denotes the real part of the complex function contained within the brackets. In this equation, the lowercase subscripts, i and j, denote the responses being correlated. A set of design loads, PLj, correlated to the design limit load PLi, are then calculated as follows:

P𝐿𝑗= 𝑃(1−𝑔)𝑗± 𝑈𝜎 𝜌𝑖𝑗 𝐴𝑗

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-152A

Listed as related material by

Source-backed
Evidence and scope

AMC 20-152A §8(a)(2)

Lists CS-25 without an amendment or specific paragraph.

Family reference; does not select a certification basis.

Supporting source

Copy reference

Select and copy the citation below.