CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
(B) Multi-Axis Gust Response - For a particular aircraft flight condition, the calculation of a specific response load requires that the amplitudes, and the time phasing, of the two gust components be chosen, subject to the condition on overall probability specified in (A) above, such that the resulting combined load is maximised. For loads calculated using a linear aircraft model, the response load may be based upon the separately tuned vertical and lateral discrete gust responses for that load, each calculated as described in Paragraph 5(b)(2) of this AMC. In general, the vertical and lateral tuned gust lengths and the times to maximum response (measured from the onset of each gust) will not be the same.
Denote the independently tuned vertical and lateral incremental responses for a particular aircraft flight condition and load quantity i by LVi and LLi, respectively. The associated multi-axis gust input is obtained by multiplying the amplitudes of the independently-tuned vertical and lateral discrete gusts, obtained as described in the previous paragraph, by 0.85*LVi/√ (LVi2+LLi2) and 0.85*LLi/√ (LVi2+LLi2) respectively. The time-phasing of the two scaled gust components is such that their associated peak loads occur at the same instant.
The combined incremental response load is given by:
2 )
𝑃𝑙𝑖= 0.85√(𝐿𝑉𝑖
2 + 𝐿𝐿𝑖
and the design limit load, PLi, corresponding to the maximum incremental load, PIi, for the given load quantity is then given by:
𝑃𝐿𝑖= 𝑃(1−𝑔)𝑖± 𝑃𝑙𝑖
where P(1-g)i is the 1-g steady load for the load quantity under consideration.
The incremental, time correlated loads corresponding to the specific flight condition under consideration are obtained from the independently-tuned vertical and lateral gust inputs for load quantity i. The vertical and lateral gust amplitudes are factored by 0.85*LVi/√ (LVi2+LLi2) and 0.85*LLi/√(LVi2+LLi2) respectively. Loads LVj and LLj resulting from these reduced vertical and lateral gust inputs, at the time when the amplitude of load quantity i is at a maximum value, are added to yield the multi-axis incremental time- correlated value PIj for load quantity j.
The set of time correlated design loads, PLj , corresponding to the peak value of the load quantity, PLi, are obtained using the expression:
𝑃𝐿𝑗= 𝑃(1−𝑔)𝑗± 𝑃𝑙𝑗
Note that with significant non-linearities, maximum positive incremental loads may differ from maximum negative incremental loads.
c. Continuous Turbulence Model.
(1) Atmosphere. The atmosphere for the determination of continuous gust responses is assumed to be one dimensional with the gust velocity acting normal (either vertically or laterally) to the direction of aeroplane travel. The one-dimensional assumption constrains the instantaneous vertical or lateral gust velocities to be the same at all points in planes normal to the direction of aeroplane travel.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Listed as related material by
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting source