CS-25
Large Aeroplanes
Amendment 28; corrected 20 November 2025 Source checked 2026-11-28
Scope, source and reading notes
Complete official CS-25 Amendment 28, including AMC and appendices.
Aerospace Consulting reference note: Certification specifications and acceptable means of compliance for large aeroplanes, using the corrected official publication.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 32f1a9acf26e8ceceb291d206bf07a7071f7f59f40f10c096bb17f34c6a58007
This AMC applies to centralised, decentralised or portable oxygen systems. Those systems may be installed in an occupied compartment or in a remote inaccessible area.
2. Related certification specifications
CS 25.869(c) Fire protection: systems — Oxygen equipment and lines
CS 25.1301 Function and installation
CS 25.1309 Equipment, systems and installations
CS 25.1441(b) Oxygen equipment and supply
CS 25.1453 Protection of oxygen equipment from rupture
3. Installation
CS 25.869(c) specifies that oxygen system equipment and lines must:
(1) not be located in any designated fire zone;
(2) be protected from heat that may be generated in, or may escape from, any designated fire zone; and
(3) be installed so that escaping oxygen cannot cause the ignition of grease, fluid, or vapour accumulations that are present in normal operation or as a result of a failure or malfunction of any system.
In addition, the following analysis and precautions should be considered.
3.1. External ignition sources
An analysis should be performed to identify all possible external ignition sources and their mechanisms. If an ignition source exists in the vicinity of the oxygen system installation, it should be demonstrated that in normal operation or in conditions that result from a failure or malfunction of any system, the risk of ignition is minimised and that all design precautions have been taken to minimise this risk.
3.2. Contamination
The compartments in which oxygen system components are installed should provide adequate protection against potential contamination by liquids, lubricants (grease, etc.), dust, etc.
3.3. Ventilation
The compartments in which oxygen system components are installed should be ventilated in such a way that, if a leak occurred or oxygen was discharged directly into the compartment (not overboard) from any protective device or pressure-limiting device, the likelihood of ignition of the oxygen-enriched environment would be minimised.
In order to support the demonstration of compliance with CS 25.869(c)(3), potential oxygen system leakage locations should be identified, and the ventilation in the area surrounding the oxygen system installation should be sufficient so that oxygen concentrations would not reach unsafe levels. If there is any area of potential high oxygen concentrations, it should be shown that this area is void of potential ignition sources, such as electrical equipment or sources of heat.
CS 25.1453(f) provides additional specifications related to ventilation.
This paragraph does not apply to portable oxygen systems, such as systems used to provide first-aid oxygen to passengers or supplemental oxygen for cabin crew mobility,