MOC-2 SC-VTOL
Means of Compliance with SC-VTOL — Batch 2
Issue 3 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 2 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Second final batch of means of compliance. Adds and revises earlier material; MOC VTOL.2105 was excluded from this final publication for further revision.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 1fcaf1c7db56acce38f5379ba2117f1137dbc35be3fa6ee4136a0f572d856136
Doc. No: MOC-2 SC-VTOL Issue: 3 Date: 22 Dec 2022
Condition VTOL
Protection against the effects of fire
(a) Fire protection of flight controls, lift/thrust unit mounts, and other flight structure: Flight controls,
lift/thrust unit mounts and other flight structure located in the Fire Withstanding Zone, the Designated Fire Zone, the Explosive Fire Zone or in adjacent areas subject to the effects of fire, heat or arc-faults should be constructed of materials or shielded to withstand the effects of fire, so that they can perform their essential function at the most adverse operating condition.
(b) Areas adjacent to a Fire Withstanding Zone, a Designated Fire Zone or an Explosive Fire Zone:
Components, electrical lines and fittings (including fire detection components, if any), located in area adjacent to a Fire Withstanding Zone, a Designated Fire Zone or an Explosive Fire Zone should be constructed of such materials and located such that if a portion of the lift/thrust unit or EESS is subject to fire, heat or arc-faults, the following is ensured:
continued safe flight and landing, for Category Enhanced VTOL aircraft, or controlled emergency landing, for Category Basic VTOL aircraft.
(c) Drainage and ventilation of Fire Withstanding Zone, Designated Fire Zone and Explosive Fire Zone:
There should be a complete drainage of each part of each Fire Withstanding Zone or Explosive Fire Zone if any presence of fluids can occur. The drainage means should be:
(i) effective under conditions expected to prevail when drainage is needed; and (ii) arranged so that no discharged fluids or gases, smoke, soot, particulate will cause an
additional hazard.
In absence of efficient draining, especially in case of limited amount of fluids in EESS, these fluids can be contained within the zone, which then should be capable to resist the increased fire threat. Each Fire Withstanding Zone or Explosive Fire Zone should be ventilated/exhausted to prevent the accumulation of hazardous gases, smoke, soot, particulate. No ventilation opening may be where it would allow the entry of fluids, of hazardous gases, smoke, soot, particulate or flame from other zones. The ventilation means should be:
(i) effective under conditions expected to prevail when ventilation is needed, and (ii) arranged so that no discharge of gases, smoke, soot, particulate or flame will cause an
additional hazard or impinge occupants or persons on the ground (refer to Hazard Areas, as defined in paragraph (d) of MOC VTOL.2400(c)(3)).
(d) Disconnect mechanism
For each EESS there should be a means to quickly disconnect, either manually by the flight crew or automatically, and isolate the battery from the main electrical circuit during operation. For each lift/thrust unit there should be a means to quickly disconnect, either manually by the flight crew or automatically, and isolate the engine from the main electrical circuit during operation. If a manual disconnection means for a lift/thrust unit is implemented, it should be ensured that the connection can be e-established in flight.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.