Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 1fcaf1c7db56acce38f5379ba2117f1137dbc35be3fa6ee4136a0f572d856136
Doc. No: MOC-2 SC-VTOL Issue: 3 Date: 22 Dec 2022
Condition VTOL
A closed volume is a volume designed for a complete retention/ containment of fire – it does not preclude from draining or ventilation features that do not impact the fire containment capabilities of the volume or zone.
(g) Open Volume: An open volume is a volume designed for a partial retention/ containment of fire. The concept of open volume is applied on the FWZ. It prevents fire propagation by an appropriate choice of materials.
(h) Fire withstanding capability (Electrical lift/thrust unit fire):
The fire withstanding capability is the capability required of a Fire Withstanding Zone for electric lift/thrust unit installation, for a fire not confined in a Designated Fire Zone as defined in CS 29.1181(a).
This capability can be shown:
by the test in section 3(e)(4) of this MOC, or following a fire threat characterisation of the electrical lift/thrust unit proposed by the applicant and accepted by EASA. This characterisation should be performed using the design, the material characteristics, power, etc. and should then be used to demonstrate the zone’s robustness against a fire threat.
(i) Explosive fire capability (Electrical Energy Storage System fire):
The explosive fire capability is the capability required to contain a thermal runaway of the propulsion batteries as defined in the accepted standards or means of compliance.
Applicability and Scope
This MOC VTOL.2330 will be developed in an incremental approach according to the following steps:
(a) Step 1: Air cooled engine with rechargeable batteries as electrical energy storage system not liquid
cooled, (b) Step 2: Air cooled engine with liquid cooled battery (oil, glycol water, etc…), (c) Step 3: Other energy storage technologies (e.g. fuel cells, capacitors) or hybrid propulsion. For instance:
liquid cooled engine with liquid cooled battery.
The MOC at hand provides guidance and methods for addressing the fire protection of the installation of electric propulsion systems in VTOL using rechargeable batteries as electrical energy storage system not liquid cooled [step 1]. Some provisions for steps 2 and 3 have already been included in this step 1 for clarity purpose, especially the definition of Designated Fire Zone in the VTOL context, and will be completed in the subsequent steps. For different energy storage technologies (e.g. fuel cells, capacitors) or hybrid propulsion systems this MOC is not yet applicable and will be completed [steps 2 and 3].
The certification of electric engines and propellers is not part of this MOC.
This MOC does not cover or replace applicable regulations for qualification, handling, storage, transport, and disposal of batteries.
It is applicable to VTOL Aircraft in Category Basic and Enhanced.
This MOC can also be followed to demonstrate compliance with VTOL.2325 and VTOL.2440, where applicable.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-2 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source