MOC-2 SC-VTOL
Means of Compliance with SC-VTOL — Batch 2
Issue 3 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 2 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Second final batch of means of compliance. Adds and revises earlier material; MOC VTOL.2105 was excluded from this final publication for further revision.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 1fcaf1c7db56acce38f5379ba2117f1137dbc35be3fa6ee4136a0f572d856136
Doc. No: MOC-2 SC-VTOL Issue: 3 Date: 22 Dec 2022
Condition VTOL
In-Service Continued Structural Robustness
(i) Regular non-destructive inspections (NDI) (ii) Limited repairs permitted without TC Holder support (iii) End of flight reports of relevant parameters, for example, vibration, loads, deflection,
temperature, acoustic emission (iv) Active in-flight monitoring with pilot notification (v) In-Service Monitoring to verify the health and operating conditions and the
effectiveness of design and maintenance provisions, as well as other procedures, throughout the life of the type design., refer to MOC VTOL.2240(e) (vi) Health and Usage Monitoring System (HUMS), refer to MOC VTOL.2240(e) (vii) Notification required to the TC Holder of any unusual or unexpected wear or
deterioration of parts in service
For some elements the determination of the failure rate could be more appropriately determined using other cycles, such as flight cycles or centrifugal force cycles. A conservative spectrum should then be used to convert the structural failure rate into probability per flight hour.
Note: The following text is added to MOC VTOL.2250(c) in Doc. No. MOC SC-VTOL, Issue 2
(c) In the safety assessment in (a)(3) of this MOC related to bearings, as a minimum and when applicable,
the following failure modes of bearings should be considered:
rupture of one or several of the bearing constituents partial or complete seizure of the bearing advanced spalling of bearings races or rolling elements advanced wear of bearing rings, rolling elements or cages loss of bearing preload permanent deformation
MOC VTOL.2250(e) Doors, canopies and exits
Scope and Definitions
(a) This paragraph applies to: All doors, hatches, openable windows, access panels, covers, etc., on the exterior of the vehicle. (b) However, this paragraph does not apply if the door requires a specific tool to both open and close the door. (c) This paragraph also does not apply if the opening of the door, in any flight phase, would not cause an event worse than Minor, as defined in VTOL.2510. The potential of persons inadvertently falling from the vehicle, and the physiological effect on passengers, should be included in the event classification, in addition to effects on the vehicle structure, systems, controllability etc. (d) Latches are movable mechanical elements that, when engaged, prevent the door from opening. (e) Latched means the latches are engaged with their structural counterparts and held in position by the latch operating mechanism. (f) Structural aspects of Door design, and Emergency Egress from the vehicle are out of scope of this paragraph. Refer to VTOL.2315(a) for emergency egress and Subpart C for the structural aspects.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-2 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source