CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
(2) Demonstration of performance
Adequate performance should be demonstrated in accordance with paragraph (f) of this AMC. Additional considerations are listed below taking into account that the demonstration of performance is to be commensurate with the role of the VHM system from an airworthiness perspective:
(i) The applicant should define the necessary indicators and alerting criteria to ensure that all components specified in the scope defined in (1) above are adequately monitored taking into account the failures to be prevented as identified in the safety analysis required by CS 29.1465(b)(1). When doing this, the applicant may experience difficulties to ensure that the defined criteria are effective to prevent premature failure while maintaining acceptable false alarm rates without applicable and representative direct evidence. This may be the case of, for example, rotor or rotor drive system components whose condition indicators are too low or too scattered, preventing the definition of appropriate learnt thresholds, and for which representative computed indicators from healthy and eventually also degraded components are required to define effective and reliable fixed thresholds or threshold learning algorithms.
Therefore, in support of the definition of alerting criteria for VHM applications for compliance with an operational regulation, the applicant should consider the following:
(A) For those components for which experience has shown that thresholds defined in the absence of applicable test or in-service data of a component subject to damage or degradation are not reliable and/or effective, the applicant may propose to approve the system without defined alerting criteria for those components (see (3) below for further guidance on establishing alerting criteria during the CSI).
(B) Data gathered from service should be statistically analysed to ensure that the alerting criteria are adequately set to indicate the presence of damage or degradation. This may require the evaluation of components replaced or repaired due to a VHM alert to verify that their condition was in line with the VHM indication.
(C) VHM data from components identified through other means as damaged or degraded and whose condition should have been indicated by the VHM system should be investigated. If deemed necessary, the alerting criteria should be amended.
(ii) It is not expected that direct evidence is developed to support the performance demonstration for this kind of VHM system applications.
(iii) Nevertheless, it should be demonstrated that the VHM system design and the implemented monitoring approach are expected to provide an adequate fault detection performance at the time of the approval. This should be achieved by justifying that the monitoring approach relied upon for each monitored component provides reasonable chances of early detection against the risk of premature failure. For this purpose, indirect evidence means from those listed in (f)(2)(ii)(B), as well as service experience from existing systems, where available, should be used to:
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source