CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
(2) retracted;
considering the possibility of fire.
(b) Passenger entrance, crew, and service doors may be considered as emergency exits if they meet the requirements of this paragraph and of CS 29.805 to 29.815.
(c) If certification with ditching provisions is requested by the applicant:
(1) ditching emergency exits must be provided such that following a ditching, in all sea conditions for which ditching capability is requested by the applicant, passengers are able to evacuate the rotorcraft and step directly into any of the required life rafts;
(2) any exit provided for compliance with (1), irrespective of whether it is also required by any of the requirements of CS 29.807, must meet all the requirements of CS 29.809(c), CS 29.811(a), (c), (d), (e) and CS 29.812(b); and
(3) flotation devices, whether stowed or deployed, may not interfere with or obstruct the ditching emergency exits.
(d) Except as provided in sub-paragraph (e), the following categories of rotorcraft must be tested in accordance with the requirements of Appendix D to demonstrate that the maximum seating capacity, including the crew-members required by the operating rules, can be evacuated from the rotorcraft to the ground within 90 seconds:
(1) Rotorcraft with a seating capacity of more than 44 passengers.
(2) Rotorcraft with all of the following:
(i) Ten or more passengers per passenger exit as determined under CS 29.807(b).
(ii) No main aisle, as described in CS 29.815, for each row of passenger seats.
(iii) Access to each passenger exit for each passenger by virtue of design features of seats, such as folding or break-over seat backs or folding seats.
(e) A combination of analysis and tests may be used to show that the rotorcraft is capable of being evacuated within 90 seconds under the conditions specified in CS 29.803(d) if the Agency finds that the combination of analysis and tests will provide data, with respect to the emergency evacuation capability of the rotorcraft, equivalent to that which would be obtained by actual demonstration.
[Amdt No: 29/5]
Appendix D – Criteria for demonstration of emergency evacuation procedures under CS 29.803
ED Decision 2003/16/RM
(a) The demonstration must be conducted either during the dark of the night or during daylight with the dark of night simulated. If the demonstration is conducted indoors during daylight hours, it must be conducted inside a darkened hangar having doors and windows covered. In addition, the doors and windows of the rotorcraft must be covered if the hangar illumination exceeds that of a moonless night. Illumination on the floor or ground may be used, but it must be kept low and shielded against shining into the rotorcraft’s windows or doors.
(b) The rotorcraft must be in a normal attitude with landing gear extended.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source