EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-29

Large Rotorcraft

Amendment 12 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-29 Amendment 12.

Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66

Source page 360 · PDF page 360

— that provides 10 minutes of electrical power to operate both the recorder and the cockpit-mounted area microphone; and

— to which the recorder and the cockpit-mounted area microphone are switched automatically in the event that all other power to the recorder is interrupted either by a normal shutdown or by any other loss of power.

(e) The container of the recording medium must be located and mounted so as to minimise the probability of the container rupturing, the recording medium being destroyed, or the underwater locating device failing as a result of any possible combinations of:

— impact with the Earth’s surface;

— the heat damage caused by a post-impact fire; and

— immersion in water.

(f) If the cockpit voice recorder has an erasure device or function, the installation must be designed to minimise the probabilities of inadvertent operation and of actuation of the erasure device or function during crash impact.

(g) The recorder container of the cockpit voice recorder must:

(1) be bright orange;

(2) have reflective tape affixed to its external surface to facilitate locating it; and

(3) have an underwater locating device on or adjacent to the container which is secured in such a manner that they are not likely to be separated during crash impact.

[Amdt 29/7] [Amdt 29/9]

AMC 29.1457 Cockpit Voice Recorders

ED Decision 2021/010/R

This AMC provides further guidance and acceptable means of compliance to supplement FAA AC 29- 2C § AC 29.1457. § 29.1457, to meet EASA's interpretation of CS 29.1457. As such, it should be used in conjunction with the FAA AC.

1. General

The installation of a recorder with an ETSO authorisation against ETSO-C123c (or equivalent standard accepted by EASA) satisfies the approval requirement in CS 29.1457(a).

In showing compliance with CS 29.1457, the applicant should take into account EUROCAE Document ED 112A ‘MOPS for Crash-Protected Airborne Recorder Systems’ or a later revision.

‘CVR system’ designates the cockpit voice recorder (CVR) and its dedicated equipment (e.g. dedicated sensors or transducers, amplifiers, dedicated data buses, dedicated power source).

2. Automatic means to stop the recording after a crash impact

The automatic means to stop the recording within 10 minutes after a crash impact may rely on:

a. Dedicated crash impact detection sensors. In this case, negative acceleration sensors (also called ‘g-switches’) should not be used as the sole means of detecting a crash impact; or

b. The recording start-and-stop logic, provided that this start-and-stop logic stops the recording 10 ± 1 minutes after the loss of power on all engines.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.