CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
POWERPLANT CONTROLS AND ACCESSORIES
CS 29.1141 Powerplant controls: general
ED Decision 2003/16/RM
(a) Powerplant controls must be located and arranged under CS 29.777 and marked under CS 29.1555.
(b) Each control must be located so that it cannot be inadvertently operated by persons entering, leaving or moving normally in the cockpit.
(c) Each flexible powerplant control must be approved.
(d) Each control must be able to maintain any set position without:
(1) Constant attention; or
(2) Tendency to creep due to control loads or vibration.
(e) Each control must be able to withstand operating loads without excessive deflection.
(f) Controls of powerplant valves required for safety must have:
(1) For manual valves, positive stops or in the case of fuel valves suitable index provisions, in the open and closed position; and
(2) For power-assisted valves, a means to indicate to the flight crew when the valve:
(i) Is in the fully open or fully closed position; or
(ii) Is moving between the fully open and fully closed position.
CS 29.1142 Auxiliary power unit controls
ED Decision 2003/16/RM
Means must be provided on the flight deck for starting, stopping, and emergency shutdown of each installed auxiliary power unit.
CS 29.1143 Engine controls
ED Decision 2003/16/RM
(a) There must be a separate power control for each engine.
(b) Power controls must be arranged to allow ready synchronisation of all engines by:
(1) Separate control of each engine; and
(2) Simultaneous control of all engines.
(c) Each power control must provide a positive and immediately responsive means of controlling its engine.
(d) Each fluid injection control other than fuel system control must be in the corresponding power control. However, the injection system pump may have a separate control.
(e) If a power control incorporates a fuel shutoff feature, the control must have a means to prevent the inadvertent movement of the control into the shutoff position. The means must –
(1) Have a positive lock or stop at the idle position; and
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source