CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
(c) The placard must state whether the calibration was made with radio receivers on or off.
(d) Each calibration reading must be in terms of magnetic heading in not more than 45° increments.
CS 29.1549 Powerplant instruments
ED Decision 2023/001/R
For each required powerplant instrument, as appropriate to the type of instruments –
(a) Each maximum and, if applicable, minimum safe operating limit must be marked with a red line;
(b) Each normal operating range must be depicted as a green or unmarked range;
(c) Each take-off and precautionary range must be marked with a yellow range or yellow line;
(d) Each engine or propeller range that is restricted because of excessive vibration stresses must be marked with red ranges or red lines; and
(e) Each OEI limit or approved operating range must be marked to be clearly differentiated from the markings of sub-paragraphs (a) to (d) except that no marking is normally required for the 30-second OEI limit.
[Amdt No: 29/11]
CS 29.1551 Oil quantity indicator
ED Decision 2003/16/RM
Each oil quantity indicator must be marked with enough increments to indicate readily and accurately the quantity of oil.
CS 29.1553 Fuel quantity indicator
ED Decision 2003/16/RM
If the unusable fuel supply for any tank exceeds 3.8 litres (0.8 Imperial gallon/1 US gallon), or 5% of the tank capacity, whichever is greater, a red arc must be marked on its indicator extending from the calibrated zero reading to the lowest reading obtainable in level flight.
CS 29.1555 Control markings
ED Decision 2023/001/R
(a) Each cockpit control, other than primary flight controls or controls whose function is obvious, must be plainly marked as to its function and method of operation.
(b) For powerplant fuel controls:
(1) Each fuel tank selector valve control must be marked to indicate the position corresponding to each tank and to each existing cross feed position;
(2) If safe operation requires the use of any tanks in a specific sequence, that sequence must be marked on, or adjacent to, the selector for those tanks; and
(3) Each valve control for any engine of a multi-engine rotorcraft must be marked to indicate the position corresponding to each engine controlled.
(c) Usable fuel capacity must be marked as follows:
(1) For fuel systems having no selector controls, the usable fuel capacity of the system must be indicated at the fuel quantity indicator unless it is:
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source