CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
— a high number of sources of variability are identified;
— some sources whose impact may be significant are not evaluated; and/or
— substantial scatter in the likelihood of detection is observed;
(3) consider that a ‘non-complex’ VHM application typically features:
— simple and industry proven system architecture and sensors;
— standard and industry proven processing techniques;
— vibration signals that are directly attainable with limited noise or interfering signals;
— vibrations signals that are understood to be a consequence of the damage or degradation and which can be translated into condition indicators; and
— a clear increase of the likelihood of detection as the failure progresses.
(B) The ‘category’ of the VHM application defines whether ‘standard’ or ‘enhanced’ performance objectives are achieved. An application of ‘standard category’ corresponds to one that meets the minimum performance objectives for an application for credit defined above in (ii). Alternatively, the applicant may choose to demonstrate higher performance objectives (i.e. for an ‘enhanced’ VHM application). The applicant should consider the following objectives as the minimum standard for a VHM application of ‘enhanced category’:
(1) Failure progression characteristics
An ‘enhanced’ VHM application should support the determination of a PI of no less than 6 times the MIDR.
PI ≥ 6 * MIDR
(2) Likelihood of fault detection
The performance of an ‘enhanced’ application should be justified, based on the available data, to ensure that, at each opportunity at which the condition indicators are assessed against the alerting criteria following the degraded condition becoming clearly detectable, a missed detection of a damaged or degraded component is extremely unlikely.
In addition, the applicant may choose to demonstrate objectives higher than those for ‘enhanced’ applications in order to justify a greater reduction in the number of direct evidence data points.
(C) Mitigating actions used in support of or in parallel to the VHM application, if any. The applicant should consider whether any mitigating actions defined as part of the monitoring approach would be sufficient, on their own, to detect an incipient failure, given their associated detection capability and
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source