CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
periodicity in accordance with (d)(3)(i). When this is the case, the VHM application in question may be considered of a reduced ‘class’ (i.e. ‘Class 1’ would become ‘Class 2’).
Based on these criteria, the performance demonstration ‘class’ of a VHM application can be identified as follows:
Table 1: Determination of the performance demonstration ‘class’ for VHM applications for credit
VHM application ‘category’ Performance demonstration ‘class’ according to VHM application ‘category’ and ‘complexity’ Complex Non-complex Standard Class 1 Class 2 Enhanced Class 2 Class 3 This assessment may result in a different performance demonstration ‘class’ being identified for each of the aspects considered (i.e. failure mode characteristics and likelihood of detection) and, therefore, different expectations regarding the number of direct evidence data points for each.
(v) Definition of the number of direct evidence data points
The number of direct evidence data points should be established independently for the evaluation of the failure progression characteristics and the likelihood of detection.
In accordance with the considerations from (iii) above, each direct evidence data point should correspond to an independent test, unless it can be justified otherwise. Following the identification of the performance validation ‘class’ as described in (iv) above, the applicant may propose a number of direct evidence data points in accordance with Table 2 below. Additional considerations regarding the numbers specified in Table 2 and when they may need to be adjusted are listed in GM1 29.1465(f).
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source