EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-29

Large Rotorcraft

Amendment 12 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-29 Amendment 12.

Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66

Source page 388 · PDF page 388

likelihood of detection by the proposed monitoring approach. To establish this worst foreseeable scenario, the applicant should:

(1) consider the possible scenarios of failure progression, including the range of characteristics of the associated degraded conditions that may be present, how they may evolve and how they may affect the likelihood of detection;

(2) determine the maximum expected variability and scatter of the mechanical responses on the computed indicator values.

(c) For objectives (a) and (b) listed directly above, the following apply:

(1) Direct evidence data should be justified to simulate degraded conditions covering an adequate range of the possible mechanical responses generated by the failure progression.

(2) Sources of variability affecting the monitored signal(s) such as rotorcraft-to-rotorcraft, assembly, maintenance, and operating conditions should be considered. The applicant may justify that these do not significantly affect the likelihood of detection of the incipient failure. Alternatively, any sources of variability that may have a significant impact should be adequately characterised, which may require additional testing.

(3) The applicant should also consider the impact from scatter and noise signals that may be present on the rotorcraft.

(4) Only limited data from tests and/or in-service events is typically available or developed for the evaluation of the fault detection performance. Therefore, the applicant should consider service data from similar VHM applications, additional testing and/or safety factors to establish a conservative measure of the variability and scatter at the different stages of the failure progression.

(ii) Specific performance objectives

Note: The reference values provided in (A) and (B) below are approximate standards to be generally considered for VHM systems featuring credit applications. However, the applicant should consider that these may not be adequate for every application. For example, the applicant may need to fulfil more demanding objectives in cases where these reference values are not enough to meet the safety objective of a particular application. In addition, the applicant may also propose less demanding objectives in cases where, for example, mitigating actions are used in parallel to the VHM application for credit.

(A) Prognostic interval

The shortest PI expected to be experienced should be evaluated in accordance with (i)(A) above.

This PI should be demonstrated to ensure a minimum of three opportunities of detection when compared with the MIDR.

PI ≥ 3 * MIDR

(B) Likelihood of fault detection

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 29-2C

Related technical context

Engineering context
Evidence and scope

CS-29 and AC 29-2C — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.