CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
may propose to follow these. Alternatively, in case no established process is available, the following should be considered:
(a) Conservative test conditions should be defined based on the available understanding of the failure progression.
(b) Possible impacts of the progressing damage or degradation on surrounding elements should be considered.
(c) Additional tests should be considered to assess parameters affecting the variability of the failure progression. These may include any operating-, assembly-, manufacturing-, or environmental-related aspect that may impact the rate and way in which the failure progresses. Other aspects may include the characteristics (e.g. type, size, shape, orientation, etc.) of the damage or degradation.
(d) When it is not practical or technically feasible to evaluate all parameters that may impact the failure progression and/or when significant scatter is established, additional measures of conservatism may be needed. These measures may include additional conservatism applied to testing conditions and/or safety factors applied on conclusions from test results and service data.
(e) In cases where the failure progression is evaluated up to ultimate failure consequences, it should be established whether the failure progression reaches a condition from which further damage or degradation may no longer be reliably understood or conservatively evaluated, or from which the probability of detection reduces. In such cases, this point should be considered as the condition in which ultimate failure is reached.
(B) Likelihood of fault detection of the proposed monitoring approach
The likelihood of fault detection should be understood as a qualitative evaluation of the probability of the proposed monitoring approach to indicate the presence of damage or degradation at a specific point in the failure progression. In order to perform this evaluation and establish its adequacy for the intended VHM application, the applicant should pursue the following objectives:
(a) It should be demonstrated that the acquired and processed signal(s) produce consistent and reliable indicators that enable detection of the degraded condition. This should be achieved through the physical understanding of the mechanical response of the failure progression on the components being monitored and the characteristics of the VHM system. This detectable mechanical response should be demonstrated to occur systematically at some point within the failure progression and provide adequate likelihood of fault detection for the demonstrated PI.
(b) An adequate likelihood of fault detection should be ensured even for the worst foreseeable scenario from a detection point of view. This worst foreseeable scenario should be considered as a hypothetical failure progression with characteristics that result in the lowest
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source