CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
(1) Number of direct evidence data points specified in Table 2 of AMC1 29.1465(g)(2)(v)
This number has been conceived considering certain assumptions. The applicant should consider these to determine whether adjustments to the number of direct evidence data points are needed either to include additional data points or to propose fewer relative to Table 2 of AMC1 29.1465(g)(2)(v). The assumptions to be considered include:
(i) The failure progression characteristics and VHM acquisition and processing allow for several opportunities of detection within each VHM data review interval.
(ii) The monitored vibration signal and the resulting indicator values indicate an increasingly differentiated behaviour of the degraded condition as the failure progresses, which should result in a relative improvement of the detection capabilities relative to the point at which the point becomes clearly detectable.
(iii) The data available clearly supports that the statistical distributions for healthy and degraded condition are clearly differentiated. However, the separation between these distributions does not preclude false alarms or missed detections.
(iv) The conclusions from the direct evidence data points in combination with the use of conservative testing conditions and additional safety factors ensure that a safe PI and likelihood of fault detection are determined.
(v) The VHM application does not involve novel VHM system characteristics or processing techniques for which no experience is available.
(vi) The applicant has a limited available understanding of the characteristics being evaluated before the activities performed for the development and certification of the VHM application for credit in question.
(vii) The variability of the failure progression characteristics and the likelihood of detection are affected by a number of parameters, of which only a limited set can be evaluated within one direct evidence data point.
In addition, the applicant should consider that the number of direct evidence data points required for the demonstration of performance is supported by the outcome of their evaluation. For example, the initial identification of the ‘complexity’ and ‘category’ of the VHM application (in accordance with AMC1 29.1465(g)(2)(iv)(A) and (B), respectively) should be revaluated following the evaluation of the conclusions from the tests and/or service experience. This may result in the need for additional data points when the initial assumptions are not supported by the conclusions drawn from the available direct evidence.
(2) Considerations on dedicated tests
(i) Individual tests combining the evaluation of both the characteristics of the failure progression and the likelihood of detection aspects may be performed but should be carefully considered. In general, this approach may result in limitations regarding the accuracy and representativeness of the results. For example, tests dedicated to the evaluation of the characteristics of the failure progression may rely on seeded components and conservative operating conditions to fulfil their purpose, which may significantly affect the vibration signals produced. This would typically compromise the validity of the results for the purpose of evaluating the likelihood of fault detection.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.