CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
(b) determine whether a safety factor should be taken into account for uncertainties and/or to compensate for limited data. Uncertainties may include instances where service experience from similar designs is used or when there is a need to improve the confidence in the applicability of the probability of occurrence determined for the complete life of the product. Compensation for limited data may be needed when directly applicable service experience is only just enough to demonstrate the target probability of occurrence or when not all environments/types of operation are covered by the available data;
(c) consider the effects of intrinsic flaws that may be present in the part or assembly. Only those flaws that would not be detected by quality controls and/or acceptance tests need to be taken into account;
(d) detail the parameters and controls (including design, manufacturing, quality, assembly, handling, and maintenance practices) of the affected part that support the determination of the low probability of occurrence of any preceding degraded condition demonstrated at the time of the approval. This should confirm that this probability is valid and that it will not increase during the life of the product. The applicant should describe these parameters and controls and justify their adequacy based on service experience, state-of-the-art practices and safety margins;
(e) take into consideration any changes to the replacement, inspection or overhaul intervals of the affected components that may be implemented within the period used to gather the necessary service experience for this demonstration. This should verify that none of these changes may impact the validity of the probability of occurrence justified. For example, the affected part may be replaced at a certain interval, which in turn would affect its exposure to operation in the presence of defects. As a result, the data being considered for this evaluation may not be conservative if the affected part is planned to be replaced at a greater interval following introduction of VHM.
(B) In order to determine the level of alleviation that may be proposed, the applicant should evaluate the data supporting the determination of this low probability of occurrence and identify whether:
(a) it relies on directly applicable service experience. This would require sufficient operating time to be accumulated and the necessary inspections, investigations and analyses to be performed on the in- service fleet. This approach would generally result in high confidence in the probability of occurrence derived;
(b) alternatively, it mainly uses service experience from similar designs. The use of service experience from similar designs should be justified as applicable considering the design characteristics, manufacturing and quality controls, and operating conditions. This approach would generally result in lower confidence in the probability of occurrence derived.
(4) Identification of the VHM system safety objectives
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source