CS-29
Large Rotorcraft
Amendment 12 Source checked 2026-11-28
Scope, source and reading notes
Complete Easy Access Rules consolidation of CS-29 Amendment 12.
Aerospace Consulting reference note: Certification specifications and related compliance guidance for large rotorcraft, including the Amendment 12 vibration health monitoring provisions.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 37c3d4af295ea3ec222370e326c63753dabcbf00735cf671f3ad86e9d46cba66
ultimate failure; as well as, when applicable, the periodicity of the mitigating actions. It should be demonstrated that:
(A) the minimum mitigating actions provide a minimum of one opportunity to detect the degrading condition of the part. This should be understood as the completion of one inspection or one review of any indications from alternative monitoring means, within an interval in which they are justified to clearly detect the incipient failure;
(B) alternatively, extended mitigating actions, which should ensure two or more opportunities of detection, may be demonstrated to justify a greater alleviation.
For this evaluation, the applicant should consider:
— failure progression characteristics taking into account the considerations provided in (g)(2)(i)(A); and
— the detection capability of the mitigating action in question, derived from service data and/or test results, to establish the point at which the incipient failure will be detected.
(ii) The probability of occurrence of any possible preceding degraded conditions
Typically, VHM systems rely on the principle of a degraded condition preceding the failure generating a mechanical response, which can be detected by the vibration signals acquired and processed. These early signs of damage or degradation typically initiate naturally due to the normal operation of dynamic components and particularly in the presence of minor defects (e.g. indents, micropits, etc.) or slightly altered operating conditions (e.g. misalignment, wear, etc.). Such preceding degraded conditions usually develops by means of continuous operation, potentially becoming detectable at a certain point, while, if not detected, it may eventually lead to an ultimate failure.
The applicant may choose to justify that the likelihood of initiation of any possible degraded condition that may progress and ultimately lead to a failure is sufficiently low to support an alleviation of the VHM system safety objectives. For this purpose, the applicant should establish that the probability of occurrence of any preceding degraded condition is no greater than:
— 1E-05 per flight hour for catastrophic failures,
— 1E-04 per flight hour for hazardous failures, and
— 1E-03 per flight hour for major failures.
(A) As part of the determination of the probability of occurrence, the applicant should:
(a) identify the degraded conditions from which it is considered probable that such a failure may develop within the exposure time of the affected parts to operation. For this purpose, the applicant should rely on all available data, including but not limited to service experience, incidents and accidents, literature review and applicable test data. In addition, the applicant should consider that dedicated testing may be needed in support of confirming whether specific degraded conditions are likely to lead to a failure;
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
CS-29 and AC 29-2C — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source