AC 20-184A
Guidance on Testing and Installation of Rechargeable Lithium Battery and Battery Systems on Aircraft
20-184A Source checked 2026-11-28
Scope, source and reading notes
Design, installation, operation, and maintenance of rechargeable lithium batteries and battery systems under applicable airworthiness requirements.
Aerospace Consulting reference note: Testing and installation guidance for rechargeable lithium battery systems on aircraft; revision A supersedes AC 20-184.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: f2402c97abdd38bf5569f097e8f24be48e024dbf4210e6fa551ada910dcc66a7
09/18/2026
electrical impedance characteristics than lead-acid or nickel-cadmium batteries. Other components of the aircraft electrical system should be evaluated regarding these characteristics as a sy stem.
1.6 Background.
1.6.1 The proposed use of lithium batteries for equipment and systems on aircraft has prompted the FAA to review the adequacy of its guidance.
1.6.2 The users of lithium battery technology, from aircraft operators to personal computer users, consumer electronics manufacturers, and the electric vehicle industry, have noted safety problems with lithium batteries. These conditions may result from overcharging, over-discharging, flammability of cell components, and internal cell defects. In general, lithium batteries are significantly more susceptible to internal failures that can result in self-sustaining increases in temperature and pressure (that is, thermal runaway) than nickel-cadmium or lead-acid batteries.
1.6.2.1 Overcharging. Overcharging causes heating and destabilization of cell components, leading to a potentially unsafe condition. The liquid or paste-like electrolyte in lithium batteries can ignite, resulting in a self-sustaining fire or explosion. The severity of thermal runaway due to overcharging increases with increasing battery capacity because of the higher amount of electrolyte.
1.6.2.2 Over-discharging. Discharge of some types of lithium batteries beyond a certain voltage (typically 2.4 volts per cell) can cause corrosion of the cell electrodes, resulting in loss of battery capacity that cannot be reversed by recharging. This loss of capacity may not be detected by simple voltage measurements commonly available to the flightcrew when checking battery status. Additionally, over-discharging has the potential to lead to an unsafe condition such as a loss of battery capacity that may not be detected by the battery management system.
1.6.2.3 Flammability of Cell Components. Rechargeable lithium batteries use electrolytes, insulators, a nd other materials that are flammable. These materials can serve as a source of fire.
1.6.2.4 Internal Cell Defects. Undetected internal defects within a battery have the potential to cause an internal short circuit, which may lead to an unsafe condition such as an uncontrolled thermal runaway of the battery. These internal defects may not become apparent until long after the battery is in service.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-184A and 25-887-SC — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source