AC 20-184A
Guidance on Testing and Installation of Rechargeable Lithium Battery and Battery Systems on Aircraft
20-184A Source checked 2026-11-28
Scope, source and reading notes
Design, installation, operation, and maintenance of rechargeable lithium batteries and battery systems under applicable airworthiness requirements.
Aerospace Consulting reference note: Testing and installation guidance for rechargeable lithium battery systems on aircraft; revision A supersedes AC 20-184.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: f2402c97abdd38bf5569f097e8f24be48e024dbf4210e6fa551ada910dcc66a7
09/18/2026
Appendix D
the battery materials (e.g., insulation separators) when demonstrating compliance by this means.
D.3.6 Method of Compliance for SC 4.
D.3.6.1 The amendment level of § 25.863 is determined by § 21.17 or § 21.101, a s appropriate. The amendment level is not determined by the issuance or effective date of the SCs.
D.3.6.2 The ARAC draft AC 25.863-1, Flammable Fluid Fire Protection, (under development), gives acceptable guidance on § 25.863. Section 25.863 is a “fail-safe” regulation that requires means to minimize the likelihood of a fire and the resultant hazards if fire does occur.
D.3.6.3 When applying § 25.863 to a battery installation, if required by SC 4, conduct a hazard assessment assuming that a battery failure ignites any resultant flammable fluids or gases, and provide provisions to address the associated hazards. This may result in the need to provide a battery enclosure that vents overboard.
D.3.7 Method of Compliance for SC 5. Show that if fluid escapes the battery, it is not corrosive or it is managed in a way (e.g., contained, isolated, or vented overboard) to protect the surrounding structure and adjacent systems, equipment, and electrical wiring.
D.3.8 Method of Compliance for SC 6.
D.3.8.1 Show that the effects of heat, and any related effects, from the tests performed under paragraph D.3.4, Method of Compliance for SCs 3-6, do not constitute a hazard to the structure or systems of the airplane.
D.3.8.2 If the effects of the heat or any related effects constitute a hazard to the structure or systems of the airplane, design mitigation at the airplane level may be applied to bring the design into compliance with this SC.
D.3.9 Method of Compliance for SC 7. SC 7 has the same purpose as that of § 25.1309(c), but is specific to the lithium battery, which is to require flightcrew alerting if the failure of a battery installation, in itself or in relation to a system that performs an airplane-level function, could result in “unsafe system operating conditions” as stated in § 25.1309(c). The alert must meet the applicable paragraphs of § 25.1322. The applicant should refer to the current version of AC 25.1309-1B, System Design and Analysis, for guidance.
D.3.10 Method of Compliance for SC 8.
D.3.10.1 Conduct a safety assessment in accordance with § 25.1309 to determine if the flightcrew alert is a warning, caution, or advisory, taking into account
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-184A and 25-887-SC — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source