Design, installation, operation, and maintenance of rechargeable lithium batteries and battery systems under applicable airworthiness requirements.

Aerospace Consulting reference note: Testing and installation guidance for rechargeable lithium battery systems on aircraft; revision A supersedes AC 20-184.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: f2402c97abdd38bf5569f097e8f24be48e024dbf4210e6fa551ada910dcc66a7

Source page 50 · PDF page 50

09/18/2026

AC 20-184A Appendix G

runaway containment test agreed to in this appendix ( e.g., tests performed for SO 1 and 2).

2. If the effects of the heat or any related effects constitute a hazard to the

structure or systems of the airplane, mitigation at the airplane level may be applied to bring the design into compliance.

3. The temperature of the gases and the enclosure need to be provided. This temperature will help show that the effects of the heat, and any related effects, from the tests performed under SO 1 and SO 2 do not constitute a hazard to the structure or systems of the aircraft.

G.3.5.7 SO 7: Have a failure sensing and warning system to alert the flightcrew if its failure affects safe operation of the ai rplane. Method of Compliance with SO 7:

1. Ensure adequate flightcrew alerting because failure effects of a battery

installation to airplane level functions could result in unsafe system operating conditions.

2. RTCA DO-311A, section 2.1.4.2, Battery Warning Features, discusses warning circuits and signals.

G.3.5.8 SO 8: Have a monitoring and warning feature that alerts the flightcrew when its charge state falls below acceptable levels if its function is required for safe operation of the airplane. Method of Compliance with SO 8:

1. Have a means for the flightcrew and maintenance personnel to

determine the battery charge state if the battery’s function is required for safe operation of the airplane.

2. Use a system safety assessment to determine the alert level.

G.3.5.9 SO 9: Have a means to disconnect from its charging source in the event of an over-temperature condition, cell failure, or battery failure. Method of Compliance with SO 9:

1. In accordance with the applicable rules listed in paragraph 2.2.2, table

2-1, the battery must be capable of disconnecting itself from the charging source to prevent failure conditions, including satisfying SO 1 and SO 2.

2. Not applicable to the cases where RTCA DO-311A has protection disabled as a prerequisite for the test.

G.4 Method of Compliance for Very Small Rechargeable Lithium Batteries Less Than 2 Wat t-Hours. Compliance with UL 1642, UL 2054, or IEC 62133 is an acceptable method of compliance to show §23.2525 that SO 1 – S O 6, and SO 9 requirements are met for

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

25-887-SC

Related technical context

Engineering context