AC 20-184A
Guidance on Testing and Installation of Rechargeable Lithium Battery and Battery Systems on Aircraft
20-184A Source checked 2026-11-28
Scope, source and reading notes
Design, installation, operation, and maintenance of rechargeable lithium batteries and battery systems under applicable airworthiness requirements.
Aerospace Consulting reference note: Testing and installation guidance for rechargeable lithium battery systems on aircraft; revision A supersedes AC 20-184.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: f2402c97abdd38bf5569f097e8f24be48e024dbf4210e6fa551ada910dcc66a7
09/18/2026
Appendix D
APPENDIX D. ACCEPTABLE METHOD OF COMPLIANCE WITH SPECIAL CONDITIONS FOR RECHARGEABLE LITHIUM BATTERIES ON TRANSPORT CATEGORY AIRPLANES
D.1 Acceptable Methods of Compliance with Rechargeable Lithium Battery SCs. An acceptable method of compliance with the rechargeable lithium battery SCs in appendix C and related Part 25 requirements is provided in paragraphs D.3 a nd D.4. Applicants who propose the SCs in appendix C of this document for their project should submit a letter indicating this to the certification branch responsible for their project.
D.2 Issued SCs with Slightly Different Numerical Order and Wording. Prior to August 2016, the FAA issued SCs with slightly different numerical order and wording than the SCs in appendix C. The method of compliance in paragraph D.3 is also applicable to those SCs. Appendix E correlates the method of compliance in paragraph D.3 t o those SCs issued prior to August 2016.
D.3 Methods of Compliance with SCs. RTCA DO-311A, Minimum Operational Performance Standards for Rechargeable Lithium Batteries and Battery Systems, section 2.1 General Requirements provides design requirements and guidelines that are pertinent to designing safe batteries and to meeting Part 25 requirements and the SCs. Consider each of these requirements and guidelines when designing cells and batteries. The FAA does not consider appendix C of DO-311A an acceptable alternate method for battery thermal runaway containment tests (paragraph 2.4.5.5).
D.3.1 SCs 1 and 2 are intended to ensure that the cells and batteries are designed to eliminate the potential for uncontrollable failures. However, a certain number of failures may still occur due to various factors, many of which are beyond the control of the designer. Therefore, these SCs are intended to protect the airplane and its occupants even if a failure occurs.
D.3.2 These SCs are independent of each other. Demonstrating compliance with one of these
SCs does not necessarily constitute compliance with the other SCs. The following is an acceptable method of compliance for each of the SCs:
D.3.3 Method of Compliance for SCs 1 and 2.
D.3.3.1 Whereas SC 1 requires that each individual cell within a rechargeable lithium battery be designed to maintain safe temperatures and pressures, SC 2 addresses these same issues but for the entire battery. SC 2 requires that the battery be designed to prevent propagation of a thermal event, such as self-sustained, uncontrollable increases in temperature, or pressure from one cell to adjacent cells.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-184A and 25-887-SC — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source