4/25/06 AC 27-1B, Chg 2
However, many military applications, because of their demanding missions, employ
scheduled field non-destructive inspection (NDI) maintenance, (such as comparative
ultrasonics) to ensure that flaw growth either does not occur, is controlled by approved
structural repair, or by replacement of affected parts. To date, civil applications have
not been presented that desire a flaw growth, phased NDI approach. Therefore,
selection of the full-scale article’s design strain limit based on small-scale tests for a no
flaw growth design is seen to be extremely important.
(vii) Composite and adhesive properties should be determined such that
detrimental structural creep does not occur under the sustained loads and environments
expected in service. Small-scale characterization tests (such as coupon, element, and
subcomponent tests) and analysis, which verify and establish the full-scale design
criteria and parameters necessary to ensure that detrimental structural creep in
full-scale structure does not occur in service, should be conducted early in certification
and should be FAA/AUTHORITY-approved.
(viii) Material allowable strength values for full-scale design and testing
should be developed using the coupon procedures presented in MIL-HDBK-17 or
equivalent. The intent is to represent the material variability including the effects that
can occur in multiple batches of material and process runs. At least three batches of
material samples should be used in material allowable strength testing. Company
standards should be prepared, evaluated, and FAA/AUTHORITY-approved early in
certification (as part of the building block process), that reflect the material property
determination considerations recommended in MIL-HDBK-17 on a equal to or better
than basis.
(3) The third area is the protection of structure as required by § 27.609.
Protection against thermal and humidity effects and other environmental effects (e.g.,
weathering, abrasion, fretting, hail, ultraviolet radiation, chemical effects, accidental
damage, etc.) should be provided, or the structural substantiation should consider the
results of those effects for which total protection is impractical. Determination and
approval of worst-case or most conservative operating limits, and damage scenarios
should be accomplished. Appropriate flammability and fire resistance requirements
should also be considered in selecting and protecting composite structure. Usually a
threat analysis is conducted early in certification that identifies the various threats and
threat levels for which protection must be provided. This data is then used to construct
and submit for approval the methods-of-compliance necessary to provide proper
structural protection.
(4) The fourth area is the lightning protection requirements of § 27.610.
Protection should be provided and substantiated in accordance with analysis and with
tests such as those of AC 20-53A and FAA Report DOT/FAA/CT-86/8. For composite
structure projects involving rotorcraft certified to earlier certification bases (which do not
automatically include the lightning protection requirements of § 27.610), these
requirements should be imposed as special conditions. The design should be reviewed
early in certification to ensure proper protection is present. The substantiation test
Page MG 8 - 13