3/31/2014 AC 27-1B, Chg 4
AC 27.1309. § 27.1309 (Amendment 27-21) EQUIPMENT, SYSTEMS, AND
INSTALLATIONS.
a. Types of Equipment. Section 27.1309 of the Title 14 CFR regulations covers,
but is not limited to, electrical, pneumatic, and hydraulic power sources, distribution, and
corresponding utilization systems.
b. Environmental Qualification.
(1) Laboratory Tests.
(i) Environmental Standards. In order to ensure that the components and
systems under consideration will function properly when exposed to adverse
environments, they should be tested in the laboratory under a simulated adverse
environment. If a TSO exists and it is appropriate in environmental range and
performance for an equipment installation, it is preferable that the equipment be TSO
approved. If there is no applicable TSO or an existing TSO does not provide for a
sufficiently adverse environment, the latest revision of Radio Technical Commission for
Aeronautics (RTCA) Document DO-160 is an acceptable environmental standard for
laboratory qualification of aircraft equipment.
(ii) Adverse environmental variables for all types of required and critical
equipment include, but are not necessarily limited to, temperature, humidity, vibration,
shock, altitude, overpressure, and power source transients.
(iii) For electrical and electronic equipment, adverse environmental
variables include all of (b)(1)(i) and (ii) above plus overvoltage and undervoltage.
Electronic equipment should also be tested for electromagnetic interference (EMI).
These tests should include both emission and susceptibility evaluations of both
conducted and radiated EMI.
(iv) Explosion Tests. Those items of electrical and electronic equipment
that are to be located in areas subject to flammable fluids and vapors, as a result of any
single probable malfunction or failure including failure of couplings or lines, should be
tested as an ignition source. These tests consist of normal operation of the equipment
in a physically contained explosive atmosphere. The explosion test procedure in the
latest revision of DO-160 will satisfy this requirement. If another standard is used that is
at least as good as the latest revision of DO-160, it may also be accepted to satisfy this
requirement.
(2) Installed Environmental Tests. After the environmental ratings of the
components and systems have been established, it should be ensured that as installed,
these ratings will not be exceeded. Normally, installed equipment need not be
instrumented and tested in flight, and it is not necessary to instrument the compartment
or rack where the equipment is installed. Satisfactory environment and equipment
compatibility are ensured by selection of the proper environmental category of
Page F - 13