6/23/23 AC 27-1B, Chg 9
AC 27.1309B. § 27.1309 (AMENDMENT 27-51) EQUIPMENT, SYSTEMS, AND
INSTALLATIONS.
a. Explanation. Amendment 27-51 revised § 27.1309 to address advances in
technology and eliminate the distinction between multi-engine and single-engine
rotorcraft. The rule now includes the same language as § 29.1309. The rule also:
Revised § 27.1309 (a) to clarify the requirements for performing a failure
analysis.
Replaced § 27.1309 (b) and (c) with language consistent with contemporary
industry practices.
b. Types of Equipment. Section 27.1309 covers, but is not limited to, electrical,
pneumatic, and hydraulic power sources, distribution, and corresponding utilization
systems.
(1) Applicability. Section 27.1309 is intended as a general requirement that is
applicable to any equipment or system as installed, in addition to specific systems
requirements, except as indicated below.
(i) General. If a specific part 27 requirement predefines systems safety
aspects (e.g., redundancy level or criticality) for a specific type of equipment, system, or
installation, then the specific part 27 requirement will take precedence. This precedence
does not preclude accomplishment of a system safety assessment, if necessary. For
example, § 27.695 predefines a required level of redundancy and an implied level of
system reliability. However, a system safety assessment approach may still be required
to show that the implied system reliability is met and to address assessment of the
failure modes.
(ii) Section 27, Subparts B, C, and D. Section 27.1309 does not apply to the
design features required by Subparts B, C, and D of part 27 for aspects such as the
performance, flight characteristics, structural loads, and structural strength. However,
the requirements in § 27.1309 do apply to any equipment and system that the proposed
design uses to comply with the requirements of Subparts B, C, and D (e.g., Health
Usage Monitoring System certified for maintenance credit and Stability Augmentation
System).
(iii) Section 27, Subpart E.
Page F - 30.1