4/25/06 AC 27-1B, Chg 2
(46) PASSIVE MULTIPLE LOAD PATH. Structure providing load paths with
one or more of the members (or areas of a member) relatively unloaded until failure of
the other member or members.
(47) ACCIDENTAL DAMAGE FLAWS. Discrete damage that may occur in
service use or in manufacturing due to impacts or collisions, such as dents, scratches,
gouges, abrasions, disbonds, splintering, and delaminations.
(48) MANUFACTURING-RELATED FLAWS. Intrinsic imperfections related to
manufacturing operations, processing, or assembly such as voids, gaps, porosity,
inclusions, fiber dislocation, disbonds, and delaminations.
(49) FATIGUE/ENVIRONMENTAL FLAWS. Structural damage related to
fatigue or environmental effects such as delaminations, disbonds, splintering, or
cracking.
(50) DESIGN LIMIT LOADS. The maximum loads to be expected in service,
as defined by § 27.301(a).
(51) AS-MANUFACTURED. Product or component that has passed the
applicable quality control process and has been found to conform to the approved
design within the allowable tolerances.
(52) RESIDUAL STRENGTH. The strength retained for some period of
unrepaired use after a failure or partial failure due to fatigue or accidental or discrete
source of damage.
(53) PRINCIPAL STRUCTURAL ELEMENT (PSE). A structural element that
contributes significantly to the carrying of flight or ground loads and whose failure can
lead to catastrophic failure of the rotorcraft.
(54) COUPON. A small test specimen (e.g., usually a flat laminate) for
evaluation of basic lamina or laminate properties or properties of generic structural
features (e.g., bonded or mechanically fastened joints).
(55) POINT DESIGN. An element or detail of a specific design that is not
considered generically applicable to other structure for the purpose of substantiation
(e.g., lugs and major joints). Such a design element or detail can be qualified by test or
by a combination of test and analysis.
(56) ELEMENT. A generic element of a more complex structural member
(e.g., skin, stringers, shear panels, sandwich panels, joints, or splices).
(57) DETAIL. A non-generic structural element of a more complex structural
member (e.g., specific design configurated joints, splices, stringers, stringer runouts, or
major access holes).