FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 840

PDF page 840 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 840
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                     2/27/2014


      (9) Miscellaneous. Several paragraphs in this MG contain guidance for the
standards cited in the Regulatory Sections reference list (paragraph c.(1)). These
paragraphs should provide insight into designing an EMS configuration that would be
acceptable under the standards.

     (10) Oxygen. EMS oxygen installations are supplied by either liquid or gaseous
oxygen. Both types of systems are discussed in this paragraph.

            (i) Liquid Oxygen.

           (A) System General Description. Most liquid oxygen systems in use are
installed in military aircraft and, as a result, much of this material is based on experience
with these systems. A rotorcraft liquid oxygen system should be comprised of a liquid
oxygen converter, tubing, fittings, quantity gage, heat exchangers, and appropriate
pressure and flow control components as shown in figures AC 27 MG 6-1 and
AC 27 MG 6-2. The installation may provide for replenishing the liquid oxygen supply
by use of a quick-removable converter or, in the case of a fixed installation converter, by
providing external access for connection to a portable service trailer. More complicated
systems such as those with multiple converter assemblies are not discussed here since
installation of those systems are not envisioned in rotorcraft at this time.

           (B) System Components.  All components should be aircraft qualified and
suitable for use in an EMS rotorcraft application.

               (1) Liquid Oxygen Converter. A liquid oxygen converter assembly is a
self-powered system for the storage of liquid oxygen and for its conversion to gaseous
oxygen when required. A principal part of the converter assembly is a vacuum insulated
container. Pressure relief valves should be provided to allow the escape of gas
generated when oxygen is not being expended in the supply line. Oxygen losses from a
converter assembly vary from 5 to 20 percent per 24 hours depending on the size of the
container, its installation environment, and so forth. Aircraft qualified and approved
converters suitable for EMS rotorcraft use are available in either 5 or 50-liter capacities.
Size selection should be determined by flow rate and duration requirements.
Performance characteristics of each converter size are available from the manufacturer.

               (2) Shutoff Valve Assembly. This valve must be accessible to a flightcrew
member and be mounted in the supply line on or as close as possible to the outlet of the
converter. This valve provides for the confinement of the remaining supply of liquid
oxygen to the converter in the event of an emergency. Since the system pressure is
low, the use of an electrically actuated shutoff valve is satisfactory to accomplish this
function. In some installations, where the evaporating coil is immediately adjacent to
the converter, a flow fuse has been used to accomplish this function. Use of a flow fuse
must be supported by a system fault analysis and testing to show maximum normal flow
will not result in nuisance trips, and reliable trips will be provided for malfunction
conditions resulting in excess flow.



Page MG 6 - 8

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →