FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

PDF page 836

PDF page 836 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 836
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                     2/27/2014


release would be preferred over multiple action release devices. However, seats and
litters that require multiple actions to release or reposition may be acceptable if properly
evaluated to determine that, in the event of an emergency landing, there is no
obstruction or delay if rapid evacuation is necessary.

             (ii) The passenger compartment should not be partitioned to impede access to
exits. Exits and doors should be readily accessible. A door or exit is required on each
side of the rotorcraft. A demonstration or a “walk-through” of appropriate evacuation
procedures may be necessary to ensure the means and procedures are feasible and
adequate. Rotorcraft with readily accessible exits, using simple and obvious means and
procedures for an evacuation, may not require written procedures or a demonstration.
Placards and durable markings, if necessary, may be sufficient to complement the exit
markings and instructions required by the standards.

              (iii) When an evacuation demonstration is determined to be appropriate for
compliance, 90 seconds should be used as the time interval for evacuation of the
rotorcraft. Attendants and the flightcrew, trained in the evacuation procedures, may be
used to remove the litter patients.  It is preferable for the patient to remain in the litter;
however, the patient may be removed from the litter to facilitate rapid evacuation
through the exit. The patients are not ambulatory during the demonstration. Evacuation
procedures should be included if isolettes are part of the interior. The demonstration
may be conducted in daylight with the dark of the night simulated and the rotorcraft in a
normal attitude with the landing gear extended. For the purpose of the demonstration,
exits on one side (critical side) should be used. Exits on the opposite side are blocked
and not accessible for the demonstration. This is representative of a rollover or exits
blocked due to a fire.

Restraint of Occupants and Equipment. The emergency landing conditions specified in
§ 27.561(b) dictate the design load conditions. See AC 27-1, sections 27.561 and
27.785 for further information.

            (i) Whether seated or recumbent, the occupants must be protected from serious
head injury as prescribed in § 27.785. Swivel seats and tilt litters may be used provided
they are substantiated for the appropriate loads for the positions selected for approval.
Placards or markings may be used to ensure proper orientation for flight, takeoff and
landing, and emergency landing conditions. The seats and litters should be listed in the
type design data for the configuration. See paragraph b.(17) for substitutions.

             (ii) For recumbent occupants, harnesses, straps, a padded headboard, a
diaphragm, or safety belts may be used if in compliance with the load requirements of
§ 27.561(b).and § 27.785(k). Harnesses or straps are recommended. When used, they
should prevent the occupant from significant forward motion in order to reduce occupant
injuries. Infants in isolettes should be similarly protected by padding and containment
within the isolette and the isolette restrained for the load cases noted in this paragraph.
If the infant is strapped to a removable platform, there should be proper restraint of the
platform and infant within the isolette for the load cases noted in this paragraph. Isolette


Page MG 6 - 4

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →