Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Extracted text for finding words
This extraction supports search. Read the original page for complete notation and layout.
AC 27-1B, Chg 2 4/25/06
Medical Service (EMS) equipment, night sun lights, some air conditioners, video and
sound systems that require large currents (25 amps – up) to operate, Forward Looking
Infrared System (FLIRS), some forward looking radars, some weather radars, some
communication systems that transmit 30 watts or more, some data link transmission
systems, etc.
NOTE: Equipment that does not meet this criteria is considered to
be “equipment not known to have a high potential for interference.”
(B) Class of Equipment – Equipment Not Known to Have a High
Potential for Interference: Once it has been established that the equipment being
proposed to be installed is not in the class of “equipment known to have a high potential
for interference,” per the criteria stated in paragraph (2)(ii)(A), there is no requirement to
conduct the EMI installation tests described in the “EMI Installation Testing for Critical
Controls/Installation Test Conditions” paragraph (2)(iii). However, the cross-matrix
operational checks for EMC considerations described in paragraph (2)(ii) are still
required.
(iii) EMI Installation Testing for Critical Controls:
(A) EMI installation testing is no longer required for unqualified
equipment that does not have a high potential to cause interference. However, EMI
installation testing is the only method of testing to show compliance for interference
considerations, for the class of “equipment known to have a high potential for
interference.” The criteria for determining whether the “equipment is known to have a
high potential for interference” is stated in paragraph (2)(ii)(A).
(B) To accomplish the EMI installation tests, there must be an FAA-
approved test plan that requires the high interference potential equipment to be
operated through all reasonable modes of operation, in order to determine if
electromagnetic interference is entering the electronic control system. EMI installation
testing consists of interrogating the control, if it has such a feature, to determine if the
critical electronic control system is adversely affected (identify the recorded faults that
occur during the test). Additionally, real-time monitoring of the control’s input/output
parameters should be accomplished. The pass/fail criteria is “no detected interference”
for a pass state, and conversely a fail state if any interference is detected entering the
control. If interference is detected, the source of interference should be investigated to
determine if the detected interference is the worst case. In some cases, the detection of
interference may result in flight tests being required to determine if the interference is
worse in flight. After the worst case interference is defined, the interference must be
eliminated at the source, or the interference must be evaluated to assure that the critical
electronic controls, its functions, and its related indications do not result in an unsafe
condition. For FADECs, special test equipment developed by the engine manufacturer
will be required to interrogate and monitor the controls input/output parameters. Other
types critical controls may also require special test equipment to perform this type of
testing.
Page MG 4 - 12