FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-64

PDF page 673 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 673
AC 27-1B · F-64Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

AC 27-1B, Chg 4                                                     3/31/2014

         (6) Passive circuit protection has been utilized to a limited degree in some
designs. To accommodate special installation problems, unprotected wire runs of up to
2 feet have been accepted in a few instances when associated with detailed specific
installation data and regular periodic inspections. Specific installation data would
normally include information such as routing requirements, clamp locations, requirement
for conduit, etc. Electrical master junction boxes usually rely to some degree on
passive circuit protection against short circuits on distribution bars. This reliance is
normally supported by considerations such as careful layout to minimize the possibility
of shorts from loose objects, extensive use of nonconductive materials, terminal covers
for relays, etc. Periodic inspections are also normally required.  It is desirable to install
junction boxes so loose objects will tend to fall away from internal circuitry. Also, careful
consideration should be given to flammability characteristics when selecting a
nonconductive material.

AC 27.1361. § 27.1361 MASTER SWITCH.

     a. Explanation. This paragraph provides for a master switch to allow for a quick
disconnect of electric power sources. This provision was intended to minimize the
probability of electrical power providing an ignition source during a crash.

     b. Procedures.

         (1) It has been determined that bypassing the master switch with small load
circuits may not significantly increase the probability of electrical ignition of fuel.
Therefore, it is permissible to allow live circuits as described in paragraph (b) of this
section.

         (2) The pilot should be able to readily identify and operate the master switch
from his normal crew position with seat belt and shoulder harness normally adjusted.
The master switch and switch positions should be labeled. The labels should be readily
recognized under all certificated flight conditions.

         (3) Designs that include multiple power sources may include a “master switch
arrangement” instead of a “master switch.” This is done to minimize the possibility of a
single failure resulting in a total loss of electrical power.

         (4) In addition to carefully evaluating the functional aspects of an installation,
the malfunction aspects must also be considered as required by § 27.1309. Normally,
the installation is protected against inadvertent actuation of the function.





Page F - 64

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →