FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-62.6

PDF page 664 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 664
AC 27-1B · F-62.6Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

6/23/23                                         AC 27-1B, Chg 9


 thus, a means to safely contain, vent, or drain hazardous fluids or gases should be
 employed.

               (vi) Nickel cadmium (Ni-CAD) batteries have also been used for many years
  in aircraft. These batteries have a wide application from the main starting battery to
 smaller batteries integrated into individual equipment.


                (A) Twenty cell Ni-CAD batteries have been used to prevent thermal
 runaway; however, aircraft bus level voltage may not be an adequate source to properly
 charge a 20 cell Ni-CAD battery. The nominal voltage of a Ni-CAD cell is 1.5 volts and if
 the number of battery cells is 20 then; 1.5 Volts/Cell X 20 Cells = 30 volts required to
 even match the nominal voltage of the installed battery. (This is actually inadequate to
 charge the Ni-CAD cell, as a few tenth volts above that of the nominal voltage is
 required.) The maximum rotorcraft bus voltage available is typically 28.5 volts, which is
  deficient by 1.5 volts to just meet the nominal battery voltage. A compensating factor for
  this battery charging design is to require frequent battery maintenance activities. Future
 battery installation designs should not depend on the use of frequent battery
 maintenance as a compensating factor for designs that are inherently deficient in
 battery charging capability. Battery charging from the rotorcraft bus voltage is the
 prevalent method used to charge batteries, since no separate battery charger is
 needed. However, for the 20 cell Ni-CAD example, using the rotorcraft bus voltage as
 the battery-charging source can introduce battery capacity limitations. Several options
 are available to address these concerns. One option would be to use a 19-cell battery.
 Since Ni-CAD batteries were first introduced, much has been learned about their care
 and use, plus design improvements have been made that lessen the possibility of
 thermal runaways. Another approach could be to oversize the battery capacity,
 recognizing that the battery will be in a “less than” nominal capacity condition. This
 philosophy would also carry with it a Certification Maintenance Requirement.
 Compliance could also be shown by using a dedicated battery charger that can profile
 the charging based on state of charge. This can be much more efficient and make it
 possible to have a better charged battery with less frequent maintenance and increased
 battery life.

                (B)  If Ni-CAD batteries are used for engine starts and compliance with a
 requirement is achieved through the use of a temperature monitoring system, the
 temperature sensor should be located in a position that will most accurately reflect the
  internal battery temperature without causing adverse effects to the sensor. The location
 normally used is near the center of the battery. If the sensor is placed between two
  cells, the indication should be very close to the actual temperature within the cell. If the
 sensor is placed in a cell strap, there will normally be a period of time just after a heavy
 current drain (e.g., engine start) when the sensor shows a temperature that is hotter
 than the actual cell temperature.





                            Page F - 62.6

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →