FAA / Advisory circular

AC 27-1B

Certification of Normal Category Rotorcraft — Changes 1–9

Normal category rotorcraft guidance with Changes 1–9 incorporated. Search the complete AC or start with the system safety, flight controls and instrument-flight guidance.

Start with the scope.

This source includes guidance for different amendments of Part 27. Match the guidance to the aircraft’s agreed certification basis: the 27.1309 entries for Amendments 27-21, 27-46 and 27-51 are separate. The base AC was issued on 30 September 1999; Change 9 is dated 23 June 2023. The FAA catalogue’s 30 September 2008 date is not the date of the latest change.

The source, within reach.

Search within this AC, jump to a source page, or download the complete saved publication.

Download saved FAA PDF ↓

Read the source

The document, within reach.

FAA source document

Printed page F-62.3

PDF page 661 of 1196

Enlarge original ↗

Original FAA page, including its printed amendment and change markings. Extracted words support search; text reflow has not been reviewed.

Original FAA AC 27-1B, PDF page 661
AC 27-1B · F-62.3Open saved PDF here ↗
Extracted text for finding words

This extraction supports search. Read the original page for complete notation and layout.

 6//23/23
                                             AC 27-1B, Chg 9


               (A) The energy storage system capacity must be sufficient to supply the
required current at a voltage level that allows proper operation of the equipment or
functions dependent on the energy storage system. This capacity must be shown to be
sufficient at the proper voltage levels for all operational and environmental conditions,
as required by § 27.1351(a)(1). Any energy storage system required for continued safe
flight and landing of the rotorcraft must have monitoring features and the means to
indicate to the pilot the status of all critical system parameters (see § 27.1353(e)).
Accordingly, warning, caution, or advisory indication must be provided appropriate to
any hazard condition. Section 91.167 requires Rotorcrafts approved for IFR operations
have sufficient back-up power to operate a minimum set of required equipment for a
time long enough to find a suitable place to land and effect a safe landing if primary
power generation fails. The minimum time for IFR is 30 minutes. Additionally, for
rotorcraft that employ electrical power for starting, to meet the requirements in
§ 27.1351, the energy storage system must have sufficient capacity to provide adequate
engine starting on the ground, and also to provide power for the air start function, when
required. The power requirement for air start could have high-level safety considerations
depending on the rotorcraft power distribution system and the number of engines.

               (B) The energy storage system must be qualified for the specific location
and rotorcraft environment. Acceptable environmental test procedures may be found in
RTCA DO-160, which provides test procedures to meet a wide range of environmental
conditions that may exist on a wide variety of aircraft. Environmental tests should meet
or exceed the expected installation environment. In addition to the environmental
qualification, the equipment and installation design should consider the risk of explosion
presented by the production of gases that occur during normal operation or as a result
of any failed condition. An explosive resistant case or safe venting may be an
acceptable way of showing compliance if it is shown that structure and essential
systems do not suffer hazardous effects that jeopardize continued safe flight and
landing.

               (C) Energy storage systems shall have protective features to prevent
unsafe conditions during operation. The protective features shall automatically control
all critical operational parameters of the system in order to prevent any unsafe
condition. The term “automatically” is intended to preclude pilot action as a mitigating
feature and is not intended to require a specific mitigating design feature. Development
assurance levels (DAL) for hardware and software that implement monitoring and
control functions should be commensurate with the effect associated with system
failure. An acceptable certification process for airborne software is found in AC 20-115
and, for complex hardware, in AC 20-152.

               (D) The occurrence of self-sustaining, uncontrolled increases in
temperature or pressure must be prevented for normal energy storage system operation
or as a result of a failure of any part of the system installation (see § 27.1353(d)).
System architecture should ensure that a component failure does not propagate to
adjacent components. A safe design may require a compartmentalized structure to
prevent cascading failures. Any required monitoring and control functions implemented
in hardware or software should have a DAL commensurate with the hazard associated


                             Page F - 62.3

Saved from the FAA on November 17, 2026. All original pages are retained. Engineering explanations are presented separately below.

Aerospace Consulting / Engineering perspective

Start with the certification basis and the function.

Identify the applicable amendment before selecting the safety guidance. Connect intended functions and operating conditions to failure conditions, architecture decisions, common-cause considerations, verification and limitations. For flight controls and IFR work, carry the relevant 27.672, 27.1329 and Appendix B assumptions into the system safety and compliance evidence.

Explore the rotorcraft safety and certification approach →
Source edition and reading coverage

1196 original pages. 0 pages have reviewed text reflows. Original-first pages retain the source layout, with extracted text available for finding words.

Source SHA-256: 2dfac16a3644dc18997069cca78746c10726e4b70d3aba996fc87843ffe68a2b

This is a dated source copy. Automatic source acquisition is not yet scheduled.

Original FAA PDF ↗

Working through a certification question?

Bring the aircraft, the basis and the issue your team needs to resolve.

Discuss your programme →